냉각수(冷却水) 용량(容量)이 소형(小型) 디젤기관(機關)의 성능(性能)에 미치는 영향(影響) = Effect of Cooling Water Capacity on the Engine Performance for Small Diesel Engine
저자
명병수 ; 김성래 ; Myung, Byung Soo ; Kim, Soung Rai
발행기관
학술지명
Korean Journal of Agricultural Science (Korean Journal of Agricultural Science)
권호사항
발행연도
1986
작성언어
Korean
등재정보
KCI등재
자료형태
학술저널
수록면
265-278(14쪽)
제공처
동력경운기(動力耕耘機) 탑재용(塔載用) 6kW 수냉식(水冷式) 디젤기관(機關)의 성능향상(性能向上)을 도모(圖謀)하기 위(爲)하여 현존(現存)의 냉각장치(冷却裝置)는 그대로 이용(利用)하고 냉각수(冷却水) 용량(容量)만을 2700cc에서 2800cc, 2900cc, 3000cc, 3100cc 로 4수준(水準)으로 변화(變化)시키면서 기관(機關)의 출력(出力), 연료소비율(燃料消費率), Torque, 냉각수(冷却水) 및 윤활유(潤滑油)의 온도(溫度)와 기관(機關)의 마찰손실(摩擦損失)을 D.C. dynamometer를 이용(利用)하여 측정(測定)한 결과(結果)는 다음과 같은 결론(結論)을 얻었다. 1. 공시기관(供試機關)의 출력성능(出力性能)은 한국공업표준규격범위(韓國工業標準規格範圍)에는 들었으나 정격표시마력(定格表示馬力)이 실험결과(實驗結果)보다 약(約) 10% 정도(程度) 낮게 표기(表記)되어 있으며 연료소비율(燃料消費率)은 297.78g/kW-h 로 약간(若干) 높은 수준(水準)이었으며 냉각수(冷却水) 온도(溫度)는 $101^{\circ}C$로 SAE기준(基準)인 $88^{\circ}C$보다는 $13^{\circ}C$ 정도(程度)가 높았다. 2. 공시기(供試機)의 마찰손실(摩擦損失)은 정격상용회전(定格常用回轉)인 2200rpm에서 3.65kW 이었으며 기보고(旣報告)된 측정치(測定値)보다 약간(若干) 높은 범위(範圍)이었다. 3. 냉각수(冷却水) 용량(容量)을 2700cc에서 3100cc로 14.8% 증가(增加)시켰을 때 출력(出力)은 6.7kW에서 7.13kW로 0.43kW의 6.3%가 증가(增加)하였다. Torque도 냉각수(冷却水) 용량(容量) 2700cc일 때 28.85N.m에서 3100cc일 때 30.706N.m로 6.39%가 증가(增加)하는 경향(傾向)을 보였다. 4. 냉각수(冷却水) 용량(容量) 2700cc에서 3100cc로 증가(增加)시켰을 때 연료소비율(燃料消費率)은 310.85g/kW-h에서 304.14g/kW-h로 6.69g/kW-h가 감소(減少)하였으며 30분간(分間) 전하중운전시(全荷重運轉時) 냉각수(冷却水)의 온도(溫度)는 냉각수(冷却水) 용량(容量)이 2700cc에서 $101^{\circ}C$였고 냉각수(冷却水) 용량(容量)이 3100cc에서 $88^{\circ}C$로 $13^{\circ}C$가 감소하여 3100cc일 때는 SAE 표준(標準)과 같았고 윤활유(潤滑油) 온도(溫度)는 냉각수(冷却水) 용량(容量)이 2700cc일 때, $76.7^{\circ}C$였으며 냉각수(冷却水) 용량(容量)이 3100cc에서는 $70.4^{\circ}C$로 $6.4^{\circ}C$가 감소하였다. 5. 기계효율(機械效率)은 냉각수(冷却水) 용량(容量)이 2700cc에서 70.08%였고 냉각수(冷却水) 용량(容量)이 3100cc일 때는 71.08%로 0.95%가 증가(增加)하였다.
더보기This study was attempted to improve the thermal efficiency of 6 kW water-cooled diesel engine on power tiller. The engine performance tests were conducted to find out the effect of cooling water capacity of 2700cc, 2800cc, 2900cc, 3000cc, 3100cc on power, brake specific fuel consumption (BSFC), torque, temperature of cooling water and lubricating oil and friction losses of the engine with D. C. dynamometer. The results obtained in the study are summarized as follows: 1. The performance of the engine tested was adequated to Korea Industrial Standard but actual economy power was 10% higher than the labeled rated power of the engine. The BSFC of the engine tested 297.8g/kW-h which is belong a little higher level than hreign products. The temperature of cooling water was $101^{\circ}C$ which is higher than SAE standard ($88^{\circ}C$) 2. The friction losses of engine tested was 3.656 kW at 2200 rpm of rated rpm (piston speed 6.97m/sec) and is higher than those of foreign products. 3. When the cooling water capacity was increased from 2700cc to 3100cc the power output of the engine was increased from 6.7 kW to 7.13 kW at the rate of 6.4% and also the torque of the engine was increased from 28.85 N.m to 30.76 N.m at the rate of 6.39%. 4. When the cooling water capacity was increased from 2700cc to 3100cc, the BSFC was decreased 6.9g/kW-h from 310.9g/kW-h to 304.1g/kW-h, and after one half hour operation with full load, the temperature of cooling water was decreased $13^{\circ}C$ from $101^{\circ}C$ to $88^{\circ}C$ and also the temperature of lubricant oil was decreased $6.4^{\circ}C$ from $76.7^{\circ}C$ to $70.4^{\circ}C$. 5. The mechanical efficiency was increased from 70.08% to 71.08% when the cooling water capacity was increased from 2700cc to 3100cc.
더보기서지정보 내보내기(Export)
닫기소장기관 정보
닫기권호소장정보
닫기오류접수
닫기오류 접수 확인
닫기음성서비스 신청
닫기음성서비스 신청 확인
닫기이용약관
닫기학술연구정보서비스 이용약관 (2017년 1월 1일 ~ 현재 적용)
학술연구정보서비스(이하 RISS)는 정보주체의 자유와 권리 보호를 위해 「개인정보 보호법」 및 관계 법령이 정한 바를 준수하여, 적법하게 개인정보를 처리하고 안전하게 관리하고 있습니다. 이에 「개인정보 보호법」 제30조에 따라 정보주체에게 개인정보 처리에 관한 절차 및 기준을 안내하고, 이와 관련한 고충을 신속하고 원활하게 처리할 수 있도록 하기 위하여 다음과 같이 개인정보 처리방침을 수립·공개합니다.
주요 개인정보 처리 표시(라벨링)
목 차
3년
또는 회원탈퇴시까지5년
(「전자상거래 등에서의 소비자보호에 관한3년
(「전자상거래 등에서의 소비자보호에 관한2년
이상(개인정보보호위원회 : 개인정보의 안전성 확보조치 기준)개인정보파일의 명칭 | 운영근거 / 처리목적 | 개인정보파일에 기록되는 개인정보의 항목 | 보유기간 | |
---|---|---|---|---|
학술연구정보서비스 이용자 가입정보 파일 | 한국교육학술정보원법 | 필수 | ID, 비밀번호, 성명, 생년월일, 신분(직업구분), 이메일, 소속분야, 웹진메일 수신동의 여부 | 3년 또는 탈퇴시 |
선택 | 소속기관명, 소속도서관명, 학과/부서명, 학번/직원번호, 휴대전화, 주소 |
구분 | 담당자 | 연락처 |
---|---|---|
KERIS 개인정보 보호책임자 | 정보보호본부 김태우 | - 이메일 : lsy@keris.or.kr - 전화번호 : 053-714-0439 - 팩스번호 : 053-714-0195 |
KERIS 개인정보 보호담당자 | 개인정보보호부 이상엽 | |
RISS 개인정보 보호책임자 | 대학학술본부 장금연 | - 이메일 : giltizen@keris.or.kr - 전화번호 : 053-714-0149 - 팩스번호 : 053-714-0194 |
RISS 개인정보 보호담당자 | 학술진흥부 길원진 |
자동로그아웃 안내
닫기인증오류 안내
닫기귀하께서는 휴면계정 전환 후 1년동안 회원정보 수집 및 이용에 대한
재동의를 하지 않으신 관계로 개인정보가 삭제되었습니다.
(참조 : RISS 이용약관 및 개인정보처리방침)
신규회원으로 가입하여 이용 부탁 드리며, 추가 문의는 고객센터로 연락 바랍니다.
- 기존 아이디 재사용 불가
휴면계정 안내
RISS는 [표준개인정보 보호지침]에 따라 2년을 주기로 개인정보 수집·이용에 관하여 (재)동의를 받고 있으며, (재)동의를 하지 않을 경우, 휴면계정으로 전환됩니다.
(※ 휴면계정은 원문이용 및 복사/대출 서비스를 이용할 수 없습니다.)
휴면계정으로 전환된 후 1년간 회원정보 수집·이용에 대한 재동의를 하지 않을 경우, RISS에서 자동탈퇴 및 개인정보가 삭제처리 됩니다.
고객센터 1599-3122
ARS번호+1번(회원가입 및 정보수정)