This study investigated the source of electro-mechanical response of strain hardening steel-fiber-reinforced cementitious composites (SH-SFRCs) by performing the multi-fiber pullout tests combined with the electrical resistivity measurements. SH-SFRCs recently have demonstrated their self-strain or self-damage sensing capacity by utilizing the change in the electrical resistivity of SFRCs under external loading, especially tension in addition to their higher mechanical resistance, based on their unique tensile strain hardening response accompanied with multiple micro-cracks, in comparison to normal concrete and fiber-reinforced concretes (FRCs). The addition of steel fibers, highly electrically conductive material and tensile strength, in cement based composites significantly increased electrical conductivity, i.e., self-sensing capacity, as well as the superior mechanical properties including higher tensile strength and energy absorption capacity. In this study, the author assumed that the self-sensing capacity of SH-SFRCs was also much influenced by the interfacial bond characteristics between fiber and matrix because the mechanical performance of SH-SFRCs was clearly dependent on the interfacial bond strength between fiber and matrix. This study aims to further develop understanding of the self-damage sensing capability of SH-SFRCs by investigating effects of matrix cracking and interfacial bond characteristics on the electrical resistivity of steel fibers embedded in mortar matrices during fiber pullout. In addition, this study targets to detect the location of cracking in SH-SFRCs under tension by measuring the electrical resistivity responses using two or multichannel DC measurements. The study includes three major parts as follows:
First, effects of matrix cracking on the electrical resistivity of steel fibers embedded in mortar matrices during fiber pullout were investigated by using multi-fiber pullout specimens. The electrical resistivities of the steel fibers embedded in mortar matrices decreased immediately after the matrix cracking and during fiber-matrix debonding. The specimens with the two pre-designated cracks exhibited a higher reduction in the electrical resistivity than those with the one pre-designated cracks or pre-crack. The source of the self-damage sensing of SH-SFRCs in tension significantly depends on matrix cracking and fiber-matrix debonding.
Second, effects of interfacial bond characteristics on the change in electrical resistivity of strain hardening steel fiber reinforced cementitious composites under tension were investigated. The results of multi fiber pullout tests revealed that the higher interfacial bond of steel fibers generally produced more reduction in the electrical resistivity during fiber pullout. Since the strength of matrix, the geometry of fiber, and the coating materials of fiber are strongly influencing on the interfacial bond strength, their effects on the electrical resistivity were carefully investigated. High strength matrix, deformed steel fibers, and brass coating generally produced higher interfacial bond strength and consequently more reduction in the electrical resistance owing to fiber debonding. In addition, higher the number of embedded fibers bridging cracks provided higher reduction in the electrical resistivity as well.
Finally, the feasibility of using multichannel DC measurements as a tool for detecting the location of cracking in SH-SFRCs was investigated by using three different types of specimens including specimens with a cold joint, a double-edged notch, and two double-edged notches. Under direct tension, the SH-SFRCs exhibited a clear reduction in electrical resistivity of cracked zone, but not in that of the un-cracked zone. Moreover, the reduction in the electrical resistivity of cracked zone decreased as the distance between the crack position and the gauge mid-length increased. Thus, this study demonstrates that the location of cracks (or damages) in SH-SFRCs can be detected by using multichannel direct current (DC) resistivity measurements
In brief, the sources of the self-damage sensing of strain hardening steel fiber reinforced cementitious composites in tension are clear dependent on the matrix cracking, fiber debonding process, the conductivity of fibers bridging the crack, and the interfacial bond characteristics of steel fibers embedded in mortar matrices. Based on electromechanical responses of steel fibers embedded in mortar matrices, the location of crack (or damage) in SH-SFRCs in tension can be detected using multi-channel direct current resistivity measurements.
이 연구는 변형 경화 강섬유 보강 시멘트 복합재료 (strain-hardening steel-fiber-reinforced cementitious composites, SH-SFRCs)의 전기-기계적 거동에 영향을 미치는 인자에 대하여 조사하기 위해 다섬유 인발 실험 중 전기저항을 측정하였다. 최근 일반 콘크리트 및 섬유 보강 콘크리트 (fiber-reinforced concretes, FRCs)와 비교하여, 매우 높은 인장 강도 및 에너지 흡수능력을 가지는 SH-SFRCs의 전기 저항률 변화에 기반한 자기 손상 감지 능력에 대한 연구가 활발히 이루어지고 있다. 시멘트 기반 매트릭스에 높은 인장 강도 뿐만 아니라 전기적 건도성이 매우 우수한 강섬유를 첨가하여 높은 인장강도와 에너지 흡수 능력을 포함한 기계적 특성 뿐만 아니라 자가감지 능력을 가지도록 개발하였다. 이 연구에서는 매트릭스 균열과 계면 부착 특성이 섬유 인발 동안 몰탈 매트릭스에 매립되어 있는 강섬유의 전기저항에 미치는 영향을 조사함으로써 SH-SFRCs의 자기 손상 감지 능력에 대한 이해를 더하고자 하였다. 추가적으로, 두 개 또는 그 이상의 멀티채널 직류 측정을 이용하여 전기저항률 거동을 측정함으로써 SH-SFRCs의 인장 하에서 균열의 위치를 감지하고자 하였다. 이 연구의 세 가지 구성은 다음과 같다:
우선, 다섬유 인발 시험체를 사용하여 매트릭스 균열이 섬유가 인발되는 동안 모르타르 매트릭스에 매립된 강섬유의 전기저항률에 미치는 영향을 조사하였다. 모르타르 매트릭스에 매립된 강섬유의 전기저항률은 매트릭스 균열 후와 섬유와 매트릭스 사이의 탈착되는 동안에 급격하게 감소하였다. 두 개의 사전 균열이 있는 시험체는 한 개의 사전 균열 또는 사전 균열이 있는 시험체보다 더 높은 전기저항률의 감소량을 나타냈다. 인장 하중 하에서 SH-SFRCs의 자기 손상 감지는 매트릭스 균열과 섬유와 매트릭스 사이 탈착에 분명한 영향을 받는다.
다음으로, 인장 하중 하에서 계면 부착 특성이 변형 경화 강섬유 보강 시멘트 복합재료의 전기저항률에 미치는 영향을 조사하였다. 다섬유 인발 실험 결과는 강섬유의 높은 계면 부착은 일반적으로 섬유가 인발되는 동안 더 많은 전기저항률 감소를 발생시키는 것을 확인하였다. 매트릭스의 강도, 섬유의 기하학적 구조, 그리고 섬유의 코팅재료는 계면 부착강도에 영향을 미쳤으며, 이들이 전기저항률에 미치는 영향성을 조사하였다. 높은 매트릭스 강도, 변형된 강섬유, 그리고 황동 코팅은 높은 계면 부착 강도를 보였으며, 결과적으로 섬유 탈착되는 동안 더 높은 전기저항률의 감소량을 나타냈다. 게다가 균열을 연결하는 매립된 섬유의 개수가 많을수록 높은 전기저항률 감소량을 보였다.
마지막으로 SH-SFRCs의 균열 위치를 감지하기 위한 도구로써 멀티채널 직류 측정을 이용의 가능성은 직접 인장 하중 하에서 cold joint, double-edged notch, 그리고 two double-edged notches의 세가지 시험체를 사용하여 조사하였다. SH-SFRCs의 전기저항률 감소는 균열 영역에서는 명확하게 나타났지만, 비균열 영역에서는 명확히 나타나지 않았다. 게다가, 균열 영역에서의 전기저항률 감소량은 균열 위치와 gauge 중간 길이의 거리가 증가할수록 감소하였다. 즉, 이 연구는 SH-SFRCs의 균열 (또는 손상) 위치를 멀티채널 직류 저항 측정을 사용하여 감지할 수 있음을 보여준다.
요약하여, 인장 하중 하에서 변형 경화 강섬유 보강 시멘트 복합재료의 자기 손상 감지의 원인은 매트릭스의 균열, 섬유의 탈착 과정, 균열을 연결하는 섬유의 전기전도성과 모르타르 매트릭스에 매립된 강섬유의 계면 부착 특성에 분명한 영향을 받는다. 모르타르 매트릭스에 매립된 강섬유의 전기-기계적 거동을 기반으로 하여 인장 하중 하에서 SH-SFRCs의 균열 (또는 손상) 위치는 멀티채널 직류 전기저항률 측정을 사용하여 감지할 수 있다.
서지정보 내보내기(Export)
닫기소장기관 정보
닫기권호소장정보
닫기오류접수
닫기오류 접수 확인
닫기음성서비스 신청
닫기음성서비스 신청 확인
닫기이용약관
닫기학술연구정보서비스 이용약관 (2017년 1월 1일 ~ 현재 적용)
학술연구정보서비스(이하 RISS)는 정보주체의 자유와 권리 보호를 위해 「개인정보 보호법」 및 관계 법령이 정한 바를 준수하여, 적법하게 개인정보를 처리하고 안전하게 관리하고 있습니다. 이에 「개인정보 보호법」 제30조에 따라 정보주체에게 개인정보 처리에 관한 절차 및 기준을 안내하고, 이와 관련한 고충을 신속하고 원활하게 처리할 수 있도록 하기 위하여 다음과 같이 개인정보 처리방침을 수립·공개합니다.
주요 개인정보 처리 표시(라벨링)
목 차
3년
또는 회원탈퇴시까지5년
(「전자상거래 등에서의 소비자보호에 관한3년
(「전자상거래 등에서의 소비자보호에 관한2년
이상(개인정보보호위원회 : 개인정보의 안전성 확보조치 기준)개인정보파일의 명칭 | 운영근거 / 처리목적 | 개인정보파일에 기록되는 개인정보의 항목 | 보유기간 | |
---|---|---|---|---|
학술연구정보서비스 이용자 가입정보 파일 | 한국교육학술정보원법 | 필수 | ID, 비밀번호, 성명, 생년월일, 신분(직업구분), 이메일, 소속분야, 웹진메일 수신동의 여부 | 3년 또는 탈퇴시 |
선택 | 소속기관명, 소속도서관명, 학과/부서명, 학번/직원번호, 휴대전화, 주소 |
구분 | 담당자 | 연락처 |
---|---|---|
KERIS 개인정보 보호책임자 | 정보보호본부 김태우 | - 이메일 : lsy@keris.or.kr - 전화번호 : 053-714-0439 - 팩스번호 : 053-714-0195 |
KERIS 개인정보 보호담당자 | 개인정보보호부 이상엽 | |
RISS 개인정보 보호책임자 | 대학학술본부 장금연 | - 이메일 : giltizen@keris.or.kr - 전화번호 : 053-714-0149 - 팩스번호 : 053-714-0194 |
RISS 개인정보 보호담당자 | 학술진흥부 길원진 |
자동로그아웃 안내
닫기인증오류 안내
닫기귀하께서는 휴면계정 전환 후 1년동안 회원정보 수집 및 이용에 대한
재동의를 하지 않으신 관계로 개인정보가 삭제되었습니다.
(참조 : RISS 이용약관 및 개인정보처리방침)
신규회원으로 가입하여 이용 부탁 드리며, 추가 문의는 고객센터로 연락 바랍니다.
- 기존 아이디 재사용 불가
휴면계정 안내
RISS는 [표준개인정보 보호지침]에 따라 2년을 주기로 개인정보 수집·이용에 관하여 (재)동의를 받고 있으며, (재)동의를 하지 않을 경우, 휴면계정으로 전환됩니다.
(※ 휴면계정은 원문이용 및 복사/대출 서비스를 이용할 수 없습니다.)
휴면계정으로 전환된 후 1년간 회원정보 수집·이용에 대한 재동의를 하지 않을 경우, RISS에서 자동탈퇴 및 개인정보가 삭제처리 됩니다.
고객센터 1599-3122
ARS번호+1번(회원가입 및 정보수정)