KCI등재
치과 임플란트용 순 Ti의 접촉부식 거동 = The Corrosion Behavior of Pure Ti Coupled with Dental Gold Alloys
저자
김교한 (경북대학교 치과대학 치과생체재료학교실 및 생체재료연구소) ; 허만수 (경북대학교 치과대학 치과생체재료학교실 및 생체재료연구소) ; 김형일 (부산대학교 치과대학 치과재료학교실) ; 황운석 (인하대학교 공과대학 금속공학과) ; 高田 雄京 (동북대학교 치과대학 치과이공학교실) ; 奧野 攻 (동북대학교 치과대학 치과이공학교실)
발행기관
학술지명
대한치과재료학회지(THE JOURNAL OF THE KOREA RESEARCH SOCIETY FOR DENTAL MATREIALS)
권호사항
발행연도
1999
작성언어
Korean
주제어
KDC
515.12
등재정보
KCI등재
자료형태
학술저널
발행기관 URL
수록면
375-385(11쪽)
제공처
One of the fields in which titanium(Ti) is becoming increasingly valuable is the field of biomaterials. Ti had shown its good corrosion resistance, high strength to weight ratio, and compatibility with human tissues. Such applications of Ti in this area involve replacing stainless steel and cobalt-chromium alloy implant which are used in skull, shoulder joint, spine, and dental implant.
In dental field, titanium has been used as dental implant, so it becomes necessary to examine and estimate the anti-corrosion ability of Ti and its alloys at the severe conditions such as crevice corrosion and galvanic corrosion.
The purposes of this study was to examine the corrosion mechanisms of the pure Ti showing good corrosion resistance under an oral corrosion environment when it is coupled with dental casting Type Ⅱ and Type Ⅳ gold alloys. These coupling corrosion mechanisms were studied in three conditions. First was by measuring the resting potential of pure Ti, when it was uncoupled and coupled with Type Ⅱ and Type Ⅳ alloys. Second was by measuring anode polarization behavior of pure Ti, Type Ⅱ and Type Ⅳ alloys, and third was by detecting dissolved ions from the pure Ti, uncoupled and coupled with Type Ⅱ and Type Ⅳ gold alloys which were immersed in 0.9% NaCl solution for 7 days.
The resting potential showed a low potential value at the initial stage but increasing into a high value (to 0.18 V) with time elapse and reached a stable value. On the contrary, the potentials of Type Ⅱ and Type Ⅳ gold alloys were in their values at the initial stage of immersion, then decreased with the time and reached stable values, being higher than the value of pure Ti. When pure Ti coupled with Type Ⅱ and Type Ⅳ gold alloys, the resting potential of coupled one was between the values of each one.
When Type Ⅱ and Type Ⅳ gold alloys were coupled with pure Ti, there was an
increase in Ag, Cu, and Zn. Also, Zn ions released the high potential precious metal alloys, compared to the uncoupled case. Ti ion was not detected at any cases of pure Ti or coupled with gold alloys.
It was thought that one of the causes of the increase in Ag, Zn, and Cu ions when Ti was coupled with dental gold alloys was that Ag, Zn, and Cu ions were selectively dissoluted from the Ag rich regions around grain boundary and the casting defects.
In conclusions, the results of this study suggest that the pure Ti was very stable when coupled with the gold alloys in oral cavity.
분석정보
서지정보 내보내기(Export)
닫기소장기관 정보
닫기권호소장정보
닫기오류접수
닫기오류 접수 확인
닫기음성서비스 신청
닫기음성서비스 신청 확인
닫기이용약관
닫기학술연구정보서비스 이용약관 (2017년 1월 1일 ~ 현재 적용)
학술연구정보서비스(이하 RISS)는 정보주체의 자유와 권리 보호를 위해 「개인정보 보호법」 및 관계 법령이 정한 바를 준수하여, 적법하게 개인정보를 처리하고 안전하게 관리하고 있습니다. 이에 「개인정보 보호법」 제30조에 따라 정보주체에게 개인정보 처리에 관한 절차 및 기준을 안내하고, 이와 관련한 고충을 신속하고 원활하게 처리할 수 있도록 하기 위하여 다음과 같이 개인정보 처리방침을 수립·공개합니다.
주요 개인정보 처리 표시(라벨링)
목 차
3년
또는 회원탈퇴시까지5년
(「전자상거래 등에서의 소비자보호에 관한3년
(「전자상거래 등에서의 소비자보호에 관한2년
이상(개인정보보호위원회 : 개인정보의 안전성 확보조치 기준)개인정보파일의 명칭 | 운영근거 / 처리목적 | 개인정보파일에 기록되는 개인정보의 항목 | 보유기간 | |
---|---|---|---|---|
학술연구정보서비스 이용자 가입정보 파일 | 한국교육학술정보원법 | 필수 | ID, 비밀번호, 성명, 생년월일, 신분(직업구분), 이메일, 소속분야, 웹진메일 수신동의 여부 | 3년 또는 탈퇴시 |
선택 | 소속기관명, 소속도서관명, 학과/부서명, 학번/직원번호, 휴대전화, 주소 |
구분 | 담당자 | 연락처 |
---|---|---|
KERIS 개인정보 보호책임자 | 정보보호본부 김태우 | - 이메일 : lsy@keris.or.kr - 전화번호 : 053-714-0439 - 팩스번호 : 053-714-0195 |
KERIS 개인정보 보호담당자 | 개인정보보호부 이상엽 | |
RISS 개인정보 보호책임자 | 대학학술본부 장금연 | - 이메일 : giltizen@keris.or.kr - 전화번호 : 053-714-0149 - 팩스번호 : 053-714-0194 |
RISS 개인정보 보호담당자 | 학술진흥부 길원진 |
자동로그아웃 안내
닫기인증오류 안내
닫기귀하께서는 휴면계정 전환 후 1년동안 회원정보 수집 및 이용에 대한
재동의를 하지 않으신 관계로 개인정보가 삭제되었습니다.
(참조 : RISS 이용약관 및 개인정보처리방침)
신규회원으로 가입하여 이용 부탁 드리며, 추가 문의는 고객센터로 연락 바랍니다.
- 기존 아이디 재사용 불가
휴면계정 안내
RISS는 [표준개인정보 보호지침]에 따라 2년을 주기로 개인정보 수집·이용에 관하여 (재)동의를 받고 있으며, (재)동의를 하지 않을 경우, 휴면계정으로 전환됩니다.
(※ 휴면계정은 원문이용 및 복사/대출 서비스를 이용할 수 없습니다.)
휴면계정으로 전환된 후 1년간 회원정보 수집·이용에 대한 재동의를 하지 않을 경우, RISS에서 자동탈퇴 및 개인정보가 삭제처리 됩니다.
고객센터 1599-3122
ARS번호+1번(회원가입 및 정보수정)