Radiation Transmission Imaging Applications for Nuclear Reactor Systems.
저자
발행사항
Ann Arbor : ProQuest Dissertations & Theses, 2022
학위수여대학
University of Michigan Nuclear Engineering & Radiological Sciences
수여연도
2022
작성언어
영어
주제어
학위
Ph.D.
페이지수
310 p.
지도교수/심사위원
Advisor: Manera, Annalisa;Petrov, Victor.
Computational advancements in the past couple of decades have propelled the capabilities to design, model, and benchmark nuclear reactor systems. However, the lack of high-resolution two-phase flow data has hampered the development and validation of high-fidelity models for computational fluid dynamics (CFD) and subchannel codes, in particular pertaining to Light Water Reactor (LWR) systems. Radiation based methods have gained traction and are being widely deployed for the study of two-phase flows. These methods present inherit advantages over conventional instrumentation due to their non-intrusiveness as well as the capability to perform measurements through complex and opaque geometries. The present dissertation is focused on the development of in-house gamma tomography and high-speed x-ray radiography systems and their application to high-resolution two-phase flow measurements. The two measurement systems were also applied to non-destructive measurements of sodium fast reactor mock-up fuel assemblies under severe accident scenarios. A major contribution of this dissertation consisted in supporting the development and testing of the High-Resolution Gamma Tomography System (HRGTS). This is a computed tomography (CT) imaging device designed and assembled in-house at the Experimental and Computational Multiphase Flow Laboratory (ECMFL) with the purpose of performing high-spatial resolution void fraction measurements. This CT system is deployed at the Michigan Adiabatic Rod Bundle Flow Experiment (MARBLE) facility which consists of an 8 x 8 modular assembly designed to simulate scaled PWR and BWR assemblies. The present work discusses the design, construction, and operation of the MARBLE facility. This facility has been instrumented to establish a high-spatial resolution experimental database of two-phase flows inside reactor assembly geometries and investigate the effect of spacer grids and mixing vanes on void drift across subchannels. The present work discusses the design, construction, modeling, and initial measurements performed with the HRGTS at the MARBLE facility. Additionally, the high-speed x-ray radiography imaging system was assembled and deployed at the post-CHF Heat Transfer (PCHT) facility. This experiment is designed to achieve post Critical Heat Flux (CHF) conditions to investigate the following two-phase flow regimes: Inverted Annular Film Boiling (IAFB), Inverted Slug Film Boiling (ISFB) ranging to Dispersed Flow Film Boiling (DFFB). However, radiation-based measurements of boiling experiments bear several challenges due to the high temperature conditions which result in the following: mismatch of calibration to experimental conditions, x-ray beam hardening, thermal expansion, material and working fluid density. The present research focuses on developing methods to overcome these challenges and obtain meaningful quantitative results. These were validated through rigorous modeling and testing in which the aforementioned challenges are recreated. Preliminary pool boiling measurements are analyzed with the developed post-processing strategies at hand.
분석정보
서지정보 내보내기(Export)
닫기소장기관 정보
닫기권호소장정보
닫기오류접수
닫기오류 접수 확인
닫기음성서비스 신청
닫기음성서비스 신청 확인
닫기이용약관
닫기학술연구정보서비스 이용약관 (2017년 1월 1일 ~ 현재 적용)
학술연구정보서비스(이하 RISS)는 정보주체의 자유와 권리 보호를 위해 「개인정보 보호법」 및 관계 법령이 정한 바를 준수하여, 적법하게 개인정보를 처리하고 안전하게 관리하고 있습니다. 이에 「개인정보 보호법」 제30조에 따라 정보주체에게 개인정보 처리에 관한 절차 및 기준을 안내하고, 이와 관련한 고충을 신속하고 원활하게 처리할 수 있도록 하기 위하여 다음과 같이 개인정보 처리방침을 수립·공개합니다.
주요 개인정보 처리 표시(라벨링)
목 차
3년
또는 회원탈퇴시까지5년
(「전자상거래 등에서의 소비자보호에 관한3년
(「전자상거래 등에서의 소비자보호에 관한2년
이상(개인정보보호위원회 : 개인정보의 안전성 확보조치 기준)개인정보파일의 명칭 | 운영근거 / 처리목적 | 개인정보파일에 기록되는 개인정보의 항목 | 보유기간 | |
---|---|---|---|---|
학술연구정보서비스 이용자 가입정보 파일 | 한국교육학술정보원법 | 필수 | ID, 비밀번호, 성명, 생년월일, 신분(직업구분), 이메일, 소속분야, 웹진메일 수신동의 여부 | 3년 또는 탈퇴시 |
선택 | 소속기관명, 소속도서관명, 학과/부서명, 학번/직원번호, 휴대전화, 주소 |
구분 | 담당자 | 연락처 |
---|---|---|
KERIS 개인정보 보호책임자 | 정보보호본부 김태우 | - 이메일 : lsy@keris.or.kr - 전화번호 : 053-714-0439 - 팩스번호 : 053-714-0195 |
KERIS 개인정보 보호담당자 | 개인정보보호부 이상엽 | |
RISS 개인정보 보호책임자 | 대학학술본부 장금연 | - 이메일 : giltizen@keris.or.kr - 전화번호 : 053-714-0149 - 팩스번호 : 053-714-0194 |
RISS 개인정보 보호담당자 | 학술진흥부 길원진 |
자동로그아웃 안내
닫기인증오류 안내
닫기귀하께서는 휴면계정 전환 후 1년동안 회원정보 수집 및 이용에 대한
재동의를 하지 않으신 관계로 개인정보가 삭제되었습니다.
(참조 : RISS 이용약관 및 개인정보처리방침)
신규회원으로 가입하여 이용 부탁 드리며, 추가 문의는 고객센터로 연락 바랍니다.
- 기존 아이디 재사용 불가
휴면계정 안내
RISS는 [표준개인정보 보호지침]에 따라 2년을 주기로 개인정보 수집·이용에 관하여 (재)동의를 받고 있으며, (재)동의를 하지 않을 경우, 휴면계정으로 전환됩니다.
(※ 휴면계정은 원문이용 및 복사/대출 서비스를 이용할 수 없습니다.)
휴면계정으로 전환된 후 1년간 회원정보 수집·이용에 대한 재동의를 하지 않을 경우, RISS에서 자동탈퇴 및 개인정보가 삭제처리 됩니다.
고객센터 1599-3122
ARS번호+1번(회원가입 및 정보수정)