Modeling heat transfer through corrosion product deposits on fuel rods in pressurized water reactors
저자
발행기관
학술지명
권호사항
발행연도
2019
작성언어
-주제어
등재정보
SCI,SCIE,SCOPUS
자료형태
학술저널
수록면
308-319(12쪽)
제공처
<P><B>Abstract</B></P> <P>CRUD is the corrosion product deposit found on a fuel rod surface of pressurized water reactors (PWRs). Problematic phenomena caused by CRUD – CRUD Induced Power Shift (CIPS) and CRUD Induced Localized Corrosion (CILC) – are closely related to the heat transfer mechanism of CRUD. However, heat transfer regimes of CRUD are still not well clarified. Therefore, the heat transfer regimes of CRUD were investigated using existing database from the CRUD heat transfer experiment. As a result, it was found that there are three heat transfer regimes: (i) liquid-saturated regime, (ii) wick-boiling regime, and (iii) film-boiling regime. In addition, the boiling curves from the experiment were categorized according to their heat transfer regimes so that models for CRUD can be validated with appropriate database for the heat transfer regime where they are concerned. After obtaining the categorized databases, the model for the film boiling of CRUD was suggested. Unlike the conventional approaches that use capillary force as a unique source of the liquid supply in pores, the model we present in this paper adopted the disjoining force as an additional liquid supply term. This assumption was validated with the previous heat pipe experiment; the root-mean-square error (RMSE) for the prediction of the vapor film thickness was notably reduced from 790% to 18.7% by including the disjoining force to the supply term. The supply term considering the disjoining force was also applied to a model for the CRUD film boiling. The model estimates the wall superheat by balancing the supply term and the hydraulic resistance terms from fluid flows within CRUD. The model we present in this paper successfully predicted the wall superheat during the film boiling; the RMSE was 19% when the predicted wall superheats were compared with ones from the database categorized as film boiling. Finally, it was found from the sensitivity study using the model we present in this paper that the heat transfer performance of CRUD during the film boiling is highly sensitive to the pore radius.</P> <P><B>Highlights</B></P> <P> <UL> <LI> Liquid-saturated regime, wick-boiling regime, and film-boiling regime are heat transfer regimes of CRUD. </LI> <LI> Vapor film exist within the CRUD during the heat transfer regime beyond the wick-boiling regime. </LI> <LI> Disjoining force becomes dominant during film boiling when heat flux is large. </LI> <LI> Heat transfer rate during film boiling is highly sensitive to pore radius. </LI> </UL> </P>
더보기분석정보
서지정보 내보내기(Export)
닫기소장기관 정보
닫기권호소장정보
닫기오류접수
닫기오류 접수 확인
닫기음성서비스 신청
닫기음성서비스 신청 확인
닫기이용약관
닫기학술연구정보서비스 이용약관 (2017년 1월 1일 ~ 현재 적용)
학술연구정보서비스(이하 RISS)는 정보주체의 자유와 권리 보호를 위해 「개인정보 보호법」 및 관계 법령이 정한 바를 준수하여, 적법하게 개인정보를 처리하고 안전하게 관리하고 있습니다. 이에 「개인정보 보호법」 제30조에 따라 정보주체에게 개인정보 처리에 관한 절차 및 기준을 안내하고, 이와 관련한 고충을 신속하고 원활하게 처리할 수 있도록 하기 위하여 다음과 같이 개인정보 처리방침을 수립·공개합니다.
주요 개인정보 처리 표시(라벨링)
목 차
3년
또는 회원탈퇴시까지5년
(「전자상거래 등에서의 소비자보호에 관한3년
(「전자상거래 등에서의 소비자보호에 관한2년
이상(개인정보보호위원회 : 개인정보의 안전성 확보조치 기준)개인정보파일의 명칭 | 운영근거 / 처리목적 | 개인정보파일에 기록되는 개인정보의 항목 | 보유기간 | |
---|---|---|---|---|
학술연구정보서비스 이용자 가입정보 파일 | 한국교육학술정보원법 | 필수 | ID, 비밀번호, 성명, 생년월일, 신분(직업구분), 이메일, 소속분야, 웹진메일 수신동의 여부 | 3년 또는 탈퇴시 |
선택 | 소속기관명, 소속도서관명, 학과/부서명, 학번/직원번호, 휴대전화, 주소 |
구분 | 담당자 | 연락처 |
---|---|---|
KERIS 개인정보 보호책임자 | 정보보호본부 김태우 | - 이메일 : lsy@keris.or.kr - 전화번호 : 053-714-0439 - 팩스번호 : 053-714-0195 |
KERIS 개인정보 보호담당자 | 개인정보보호부 이상엽 | |
RISS 개인정보 보호책임자 | 대학학술본부 장금연 | - 이메일 : giltizen@keris.or.kr - 전화번호 : 053-714-0149 - 팩스번호 : 053-714-0194 |
RISS 개인정보 보호담당자 | 학술진흥부 길원진 |
자동로그아웃 안내
닫기인증오류 안내
닫기귀하께서는 휴면계정 전환 후 1년동안 회원정보 수집 및 이용에 대한
재동의를 하지 않으신 관계로 개인정보가 삭제되었습니다.
(참조 : RISS 이용약관 및 개인정보처리방침)
신규회원으로 가입하여 이용 부탁 드리며, 추가 문의는 고객센터로 연락 바랍니다.
- 기존 아이디 재사용 불가
휴면계정 안내
RISS는 [표준개인정보 보호지침]에 따라 2년을 주기로 개인정보 수집·이용에 관하여 (재)동의를 받고 있으며, (재)동의를 하지 않을 경우, 휴면계정으로 전환됩니다.
(※ 휴면계정은 원문이용 및 복사/대출 서비스를 이용할 수 없습니다.)
휴면계정으로 전환된 후 1년간 회원정보 수집·이용에 대한 재동의를 하지 않을 경우, RISS에서 자동탈퇴 및 개인정보가 삭제처리 됩니다.
고객센터 1599-3122
ARS번호+1번(회원가입 및 정보수정)