KCI등재
The effect of cavity wall property on the shear bond strength test using iris method = Iris 법을 이용한 전단접착강도 측정에서 와동벽의 영향
저자
Kim, Dong-Hwan (Department of Conservative Dentistry & Dental Research Institute, College of Dentistry, Seoul National University) ; Bae, Ji-Hyun (Department of Conservative Dentistry & Dental Research Institute, College of Dentistry, Seoul National University) ; Cho, Byeong-Hoon (Department of Conservative Dentistry & Dental Research Institute, College of Dentistry, Seoul National University) ; Lee, In-Bog (Department of Conservative Dentistry & Dental Research Institute, College of Dentistry, Seoul National University) ; Baek, Seung-Ho (Department of Conservative Dentistry & Dental Research Institute, College of Dentistry, Seoul National University) ; Ryu, Hyun-Mi (Department of Conservative Dentistry, The Institute of Oral Health Science, Samsung Medical Center, Sungkyunkwan University, School of Medicine) ; Son, Ho-Hyun (Department of Conservative Dentistry & Dental Research Institute, College of Dentistry, Seoul National University) ; Um, Chung-Moon (Department of Conservative Dentistry & Dental Research Institute, College of Dentistry, Seoul National University) ; Kwon, Hyuck-Choon (Department of Conservative Dentistry & Dental Research Institute, College of Dentistry, Seoul National University)
발행기관
학술지명
Restorative Dentistry & Endodontics(The Journal of Korean Academy of Conservative Dentistry)
권호사항
발행연도
2004
작성언어
English
주제어
KDC
515.000
등재정보
KCI등재
자료형태
학술저널
발행기관 URL
수록면
170-176(7쪽)
제공처
목적 : 본 연구에서는 '전단접착강도 시험법에서 cohesive failure를 줄일 수 있는 것으로 소개된 metal iris를 사용하면, 실제의 1급 와동에서보다 복합 레진과 와동벽의 결합이 없어서 C-factor 적게 작용하고 계면에 발생하는 수축응력 이 감소됨으로써, 임상에서보다 높은 결합력 값이 보고될 것이다.' 라는 가설을 검증하기 위하여 dentin iris를 사용하여 전단접착강도를 측정하였다.
방법 : 64개의 대구치를 4군으로 구분하여 metal iris와 dentin iris 군으로 구분하고, 그 각각을 ONE-STEP과 ALL-BOND 2의 두 군으로 나누었다. bonding agent를 적용하고, iris를 고정한 후, 복합 레진을 충전하여 시편을 완성하였다 이 때 dentin iris의 경우 내면에도 bonding agent를 적용하여 와동벽과의 결합이 발생하게 하였다. 전단접착강도는 24시간 후 측정하였고, 파절의 양상은 주사전자현미경과 입체광학현미경을 이용하여 결정하였다.
결과 : 전단접착강도 측정법에서 iris법을 이용함으로써 cohesive failure를 줄일 수 있다. 전단접착강도 측정법은 adhesive 두께가 얇은 경우에 와동벽의 영향을 받는다.
Objectives: In the unique metal iris method, the developing interfacial gap at the cavity floor resulting from the cavity wall property during polymerizing composite resin might affect the nominal shear bond strength values. The aim of this study is to evaluate that the iris method reduces the cohesive failure in the substrates and the cavity wall property effects on the shear bond strength tests using iris method.
Materials and Methods: The occlusal dentin of 64 extracted human molars were randomly divided into 4 groups to simulate two different levels of cavity wall property (metal and dentin iris) and two different materials (ONE-STEP® and ALL-BOND® 2) for each wall property. After positioning the iris on the dentin surface, composite resin was packed and light-cured. After 24 hours the shear bond strength was measured at a crosshead speed of 0.5 mm/min. Fracture analysis was performed using a microscope and SEM. The data was analyzed statistically by a two-way ANOVA and t-test.
Results: The shear bond strength with metal iris was significant higher than those with dentin iris (p = 0.034). Using ONE-STEP®, the shear bond strength with metal iris was significant higher than those with dentin iris (p = 0.005), but not in ALL-BOND® 2 (p = 0.774), The incidence of cohesive failure was very lower than other shear bond strength tests that did not use iris method.
Conclusions: The iris method may significantly reduce the cohesive failures in the substrates. According to the bonding agent systems, the shear bond strength was affected by the cavity wall property.
서지정보 내보내기(Export)
닫기소장기관 정보
닫기권호소장정보
닫기오류접수
닫기오류 접수 확인
닫기음성서비스 신청
닫기음성서비스 신청 확인
닫기이용약관
닫기학술연구정보서비스 이용약관 (2017년 1월 1일 ~ 현재 적용)
학술연구정보서비스(이하 RISS)는 정보주체의 자유와 권리 보호를 위해 「개인정보 보호법」 및 관계 법령이 정한 바를 준수하여, 적법하게 개인정보를 처리하고 안전하게 관리하고 있습니다. 이에 「개인정보 보호법」 제30조에 따라 정보주체에게 개인정보 처리에 관한 절차 및 기준을 안내하고, 이와 관련한 고충을 신속하고 원활하게 처리할 수 있도록 하기 위하여 다음과 같이 개인정보 처리방침을 수립·공개합니다.
주요 개인정보 처리 표시(라벨링)
목 차
3년
또는 회원탈퇴시까지5년
(「전자상거래 등에서의 소비자보호에 관한3년
(「전자상거래 등에서의 소비자보호에 관한2년
이상(개인정보보호위원회 : 개인정보의 안전성 확보조치 기준)개인정보파일의 명칭 | 운영근거 / 처리목적 | 개인정보파일에 기록되는 개인정보의 항목 | 보유기간 | |
---|---|---|---|---|
학술연구정보서비스 이용자 가입정보 파일 | 한국교육학술정보원법 | 필수 | ID, 비밀번호, 성명, 생년월일, 신분(직업구분), 이메일, 소속분야, 웹진메일 수신동의 여부 | 3년 또는 탈퇴시 |
선택 | 소속기관명, 소속도서관명, 학과/부서명, 학번/직원번호, 휴대전화, 주소 |
구분 | 담당자 | 연락처 |
---|---|---|
KERIS 개인정보 보호책임자 | 정보보호본부 김태우 | - 이메일 : lsy@keris.or.kr - 전화번호 : 053-714-0439 - 팩스번호 : 053-714-0195 |
KERIS 개인정보 보호담당자 | 개인정보보호부 이상엽 | |
RISS 개인정보 보호책임자 | 대학학술본부 장금연 | - 이메일 : giltizen@keris.or.kr - 전화번호 : 053-714-0149 - 팩스번호 : 053-714-0194 |
RISS 개인정보 보호담당자 | 학술진흥부 길원진 |
자동로그아웃 안내
닫기인증오류 안내
닫기귀하께서는 휴면계정 전환 후 1년동안 회원정보 수집 및 이용에 대한
재동의를 하지 않으신 관계로 개인정보가 삭제되었습니다.
(참조 : RISS 이용약관 및 개인정보처리방침)
신규회원으로 가입하여 이용 부탁 드리며, 추가 문의는 고객센터로 연락 바랍니다.
- 기존 아이디 재사용 불가
휴면계정 안내
RISS는 [표준개인정보 보호지침]에 따라 2년을 주기로 개인정보 수집·이용에 관하여 (재)동의를 받고 있으며, (재)동의를 하지 않을 경우, 휴면계정으로 전환됩니다.
(※ 휴면계정은 원문이용 및 복사/대출 서비스를 이용할 수 없습니다.)
휴면계정으로 전환된 후 1년간 회원정보 수집·이용에 대한 재동의를 하지 않을 경우, RISS에서 자동탈퇴 및 개인정보가 삭제처리 됩니다.
고객센터 1599-3122
ARS번호+1번(회원가입 및 정보수정)