Kim Dong-Joo (College of Korean Medicine, Dongguk University, Gyeongju, Korea) ; Jo Hyo-Rim (Department of Acupuncture & Moxibustion, Dongguk University Bundang Oriental Hospital, Seongnam, Kor) ; Jang Hansol (Department of Internal Korean Medicine, Dongguk University Bundang Oriental Hospital, Seongnam, Korea) ; Choi Seong-Kyeong (Department of Acupuncture and Moxibustion, Dongguk University, Bundang Oriental Hospital, Korea) ; Jung Chan-Yung (Department of Acupuncture & Moxibustion, Dongguk University Ilsan Oriental Hospital, Goyang, Korea) ; Sung Won-Suk (Department of Acupuncture and Moxibustion, Dongguk University, Bundang Oriental Hospital, Korea) ; Lee Seung-Deok (Department of Acupuncture) ; Lee Byung-Wook (Department of Medical Classics and History, College of Korean Medicine, Dongguk University, Gyeongju, Korea) ; Kim Eun-Jung (Department of Acupuncture & Moxibustion, Dongguk University Bundang Oriental Hospital, Seongnam, Kor)
발행기관
학술지명
권호사항
발행연도
2022
작성언어
English
주제어
등재정보
KCI등재,SCOPUS,ESCI
자료형태
학술저널
수록면
174-180(7쪽)
DOI식별코드
제공처
Background: Electronic moxibustion (EM) was developed to minimize the side effects of traditional moxibustion, such as burns, and to overcome therapeutic compliances such as smoke or smell.
Objectives: To investigate distributions and thermal stimulation of EM at various depths using silicon phantom and to compare this methodology to traditional indirect moxibustion (TIM).
Methods: A silicon phantom composed of polydimethylsiloxane was heated and immersed in a hot plate containing warm water to set the phantom’s temperature to that of biological tissue. K-type thermocouples were inserted into the phantom at depths of 0, 2, 5, 7, and 10 mm to measure temperature changes with thermal stimulation of EM or TIM placed on top of the phantom.
Results: At the surface of the phantom, the peak temperature after applying TIM (55.04 ± 0.92℃ [Δ23.79 ± 0.96℃]) was significantly higher than after EM (43.25 ± 1.95℃ [Δ13.00 ± 2.23℃]), with both interventions reaching the highest temperature after 2 minutes. The temperature increase for TIM was also statistically significant compared to EM when measured at a depth of 2 mm. For the experimental setting with TIM, after reaching peak surface temperature, a rapid decrease was observed at the surface and 2 mm while EM showed a much more gradual decline. There was no significant difference in temperature change between the groups at depths of 5, 7, and 10 mm.
Conclusion: TIM resulted in a higher temperature rise compared to EM at the surface and at a 2 mm depth reaching over 50℃, which creates risk of burns. Thermal stimulation with EM had a lower risk of burns with temperature increment not being statistically different from TIM below the depth of 5 mm.
서지정보 내보내기(Export)
닫기소장기관 정보
닫기권호소장정보
닫기오류접수
닫기오류 접수 확인
닫기음성서비스 신청
닫기음성서비스 신청 확인
닫기이용약관
닫기학술연구정보서비스 이용약관 (2017년 1월 1일 ~ 현재 적용)
학술연구정보서비스(이하 RISS)는 정보주체의 자유와 권리 보호를 위해 「개인정보 보호법」 및 관계 법령이 정한 바를 준수하여, 적법하게 개인정보를 처리하고 안전하게 관리하고 있습니다. 이에 「개인정보 보호법」 제30조에 따라 정보주체에게 개인정보 처리에 관한 절차 및 기준을 안내하고, 이와 관련한 고충을 신속하고 원활하게 처리할 수 있도록 하기 위하여 다음과 같이 개인정보 처리방침을 수립·공개합니다.
주요 개인정보 처리 표시(라벨링)
목 차
3년
또는 회원탈퇴시까지5년
(「전자상거래 등에서의 소비자보호에 관한3년
(「전자상거래 등에서의 소비자보호에 관한2년
이상(개인정보보호위원회 : 개인정보의 안전성 확보조치 기준)개인정보파일의 명칭 | 운영근거 / 처리목적 | 개인정보파일에 기록되는 개인정보의 항목 | 보유기간 | |
---|---|---|---|---|
학술연구정보서비스 이용자 가입정보 파일 | 한국교육학술정보원법 | 필수 | ID, 비밀번호, 성명, 생년월일, 신분(직업구분), 이메일, 소속분야, 웹진메일 수신동의 여부 | 3년 또는 탈퇴시 |
선택 | 소속기관명, 소속도서관명, 학과/부서명, 학번/직원번호, 휴대전화, 주소 |
구분 | 담당자 | 연락처 |
---|---|---|
KERIS 개인정보 보호책임자 | 정보보호본부 김태우 | - 이메일 : lsy@keris.or.kr - 전화번호 : 053-714-0439 - 팩스번호 : 053-714-0195 |
KERIS 개인정보 보호담당자 | 개인정보보호부 이상엽 | |
RISS 개인정보 보호책임자 | 대학학술본부 장금연 | - 이메일 : giltizen@keris.or.kr - 전화번호 : 053-714-0149 - 팩스번호 : 053-714-0194 |
RISS 개인정보 보호담당자 | 학술진흥부 길원진 |
자동로그아웃 안내
닫기인증오류 안내
닫기귀하께서는 휴면계정 전환 후 1년동안 회원정보 수집 및 이용에 대한
재동의를 하지 않으신 관계로 개인정보가 삭제되었습니다.
(참조 : RISS 이용약관 및 개인정보처리방침)
신규회원으로 가입하여 이용 부탁 드리며, 추가 문의는 고객센터로 연락 바랍니다.
- 기존 아이디 재사용 불가
휴면계정 안내
RISS는 [표준개인정보 보호지침]에 따라 2년을 주기로 개인정보 수집·이용에 관하여 (재)동의를 받고 있으며, (재)동의를 하지 않을 경우, 휴면계정으로 전환됩니다.
(※ 휴면계정은 원문이용 및 복사/대출 서비스를 이용할 수 없습니다.)
휴면계정으로 전환된 후 1년간 회원정보 수집·이용에 대한 재동의를 하지 않을 경우, RISS에서 자동탈퇴 및 개인정보가 삭제처리 됩니다.
고객센터 1599-3122
ARS번호+1번(회원가입 및 정보수정)