KCI등재
SCOPUS
Diagnostic Performance, Stability, and Usability of Self-Collected Combo Swabs and Saliva for Coronavirus Disease 2019 Diagnosis: A Case-Control Study
저자
Choi Seong Jin (Department of Internal Medicine, Seoul National University Bundang Hospital, Seoul National University College of Medicine, Seongnam, Korea.) ; Jung Jongtak (Department of Internal Medicine, Seoul National University Bundang Hospital, Seoul National University College of Medicine, Seongnam, Korea.Department of Internal Medicine, Soonchunhyang University Seoul Hospital, Soonchunhyang University College of Medi) ; Kim Eu Suk (Department of Internal Medicine, Seoul National University Bundang Hospital, Seoul National University College of Medicine, Seongnam, Korea.) ; Kim Hong Bin (Department of Internal Medicine, Seoul National University Bundang Hospital, Seoul National University College of Medicine, Seongnam, Korea.) ; Park Jeong Su (Department of Laboratory Medicine, Seoul National University Bundang Hospital, Seoul National University College of Medicine, Seongnam, Korea.) ; Park Kyoung Un (Department of Laboratory Medicine, Seoul National University Bundang Hospital, Seoul National University College of Medicine, Seongnam, Korea.) ; Lee Hyunju (Department of Pediatrics, Seoul National University Bundang Hospital, Seoul National University College of Medicine, Seongnam, Korea.) ; Lee Eunyoung (Department of Internal Medicine, Boramae Medical Center, Seoul National University College of Medicine, Seoul, Korea.) ; Choe Pyoeng Gyun (Department of Internal Medicine, Seoul National University Hospital, Seoul National University College of Medicine, Seoul, Korea.) ; Kim Ji-Yeon (Department of Internal Medicine, Seongnam Citizens Medical Center, Seongnam, Korea.) ; Lee Eun Joo (Department of Pediatrics, Seongnam Citizens Medical Center, Seongnam, Korea.) ; Song Kyoung-Ho (Department of Internal Medicine, Seoul National University Bundang Hospital, Seoul National University College of Medicine, Seongnam, Korea.) 연구자관계분석
발행기관
학술지명
권호사항
발행연도
2022
작성언어
English
주제어
등재정보
KCI등재,SCOPUS,ESCI
자료형태
학술저널
수록면
517-528(12쪽)
DOI식별코드
제공처
Background Self-sampling procedures to detect severe acute respiratory syndrome coronavirus 2 is important for patients who have difficulty visiting the hospital and may decrease the burden for health care workers (HCWs). The objective of this study was to evaluate the diagnostic performance, stability and usability of self-collected nasal and oral combo swabs and saliva specimens.
Materials and Methods We conducted a case-control study with 50 patients with coronavirus disease 2019 (COVID-19) and 50 healthy volunteers from March, 2021 to June, 2021. We performed real-time reverse-transcription polymerase chain reaction to compare the diagnostic performance of self-collected specimens using positive percent agreements (PPAs).
Results The PPAs between self-collected and HCW-collected specimens were 77.3 - 81.0% and 80.5 -86.7% for the combo swabs and saliva specimens, respectively. The PPAs increased to 88.9 - 89.2% and 81.2 - 82.1% with a cycle threshold value ≤30.
Conclusion The diagnostic performance of self sampling was comparable to that of HCW sampling in patients with high viral loads and may thus assist in the early diagnosis of COVID-19.
Background Self-sampling procedures to detect severe acute respiratory syndrome coronavirus 2 is important for patients who have difficulty visiting the hospital and may decrease the burden for health care workers (HCWs). The objective of this study was to evaluate the diagnostic performance, stability and usability of self-collected nasal and oral combo swabs and saliva specimens.
Materials and Methods We conducted a case-control study with 50 patients with coronavirus disease 2019 (COVID-19) and 50 healthy volunteers from March, 2021 to June, 2021. We performed real-time reverse-transcription polymerase chain reaction to compare the diagnostic performance of self-collected specimens using positive percent agreements (PPAs).
Results The PPAs between self-collected and HCW-collected specimens were 77.3 - 81.0% and 80.5 -86.7% for the combo swabs and saliva specimens, respectively. The PPAs increased to 88.9 - 89.2% and 81.2 - 82.1% with a cycle threshold value ≤30.
Conclusion The diagnostic performance of self sampling was comparable to that of HCW sampling in patients with high viral loads and may thus assist in the early diagnosis of COVID-19.
분석정보
서지정보 내보내기(Export)
닫기소장기관 정보
닫기권호소장정보
닫기오류접수
닫기오류 접수 확인
닫기음성서비스 신청
닫기음성서비스 신청 확인
닫기이용약관
닫기학술연구정보서비스 이용약관 (2017년 1월 1일 ~ 현재 적용)
학술연구정보서비스(이하 RISS)는 정보주체의 자유와 권리 보호를 위해 「개인정보 보호법」 및 관계 법령이 정한 바를 준수하여, 적법하게 개인정보를 처리하고 안전하게 관리하고 있습니다. 이에 「개인정보 보호법」 제30조에 따라 정보주체에게 개인정보 처리에 관한 절차 및 기준을 안내하고, 이와 관련한 고충을 신속하고 원활하게 처리할 수 있도록 하기 위하여 다음과 같이 개인정보 처리방침을 수립·공개합니다.
주요 개인정보 처리 표시(라벨링)
목 차
3년
또는 회원탈퇴시까지5년
(「전자상거래 등에서의 소비자보호에 관한3년
(「전자상거래 등에서의 소비자보호에 관한2년
이상(개인정보보호위원회 : 개인정보의 안전성 확보조치 기준)개인정보파일의 명칭 | 운영근거 / 처리목적 | 개인정보파일에 기록되는 개인정보의 항목 | 보유기간 | |
---|---|---|---|---|
학술연구정보서비스 이용자 가입정보 파일 | 한국교육학술정보원법 | 필수 | ID, 비밀번호, 성명, 생년월일, 신분(직업구분), 이메일, 소속분야, 웹진메일 수신동의 여부 | 3년 또는 탈퇴시 |
선택 | 소속기관명, 소속도서관명, 학과/부서명, 학번/직원번호, 휴대전화, 주소 |
구분 | 담당자 | 연락처 |
---|---|---|
KERIS 개인정보 보호책임자 | 정보보호본부 김태우 | - 이메일 : lsy@keris.or.kr - 전화번호 : 053-714-0439 - 팩스번호 : 053-714-0195 |
KERIS 개인정보 보호담당자 | 개인정보보호부 이상엽 | |
RISS 개인정보 보호책임자 | 대학학술본부 장금연 | - 이메일 : giltizen@keris.or.kr - 전화번호 : 053-714-0149 - 팩스번호 : 053-714-0194 |
RISS 개인정보 보호담당자 | 학술진흥부 길원진 |
자동로그아웃 안내
닫기인증오류 안내
닫기귀하께서는 휴면계정 전환 후 1년동안 회원정보 수집 및 이용에 대한
재동의를 하지 않으신 관계로 개인정보가 삭제되었습니다.
(참조 : RISS 이용약관 및 개인정보처리방침)
신규회원으로 가입하여 이용 부탁 드리며, 추가 문의는 고객센터로 연락 바랍니다.
- 기존 아이디 재사용 불가
휴면계정 안내
RISS는 [표준개인정보 보호지침]에 따라 2년을 주기로 개인정보 수집·이용에 관하여 (재)동의를 받고 있으며, (재)동의를 하지 않을 경우, 휴면계정으로 전환됩니다.
(※ 휴면계정은 원문이용 및 복사/대출 서비스를 이용할 수 없습니다.)
휴면계정으로 전환된 후 1년간 회원정보 수집·이용에 대한 재동의를 하지 않을 경우, RISS에서 자동탈퇴 및 개인정보가 삭제처리 됩니다.
고객센터 1599-3122
ARS번호+1번(회원가입 및 정보수정)