양성자 치료에서 Moving Phantom을 이용한 Single Scan PBS와 Layered Rescanning PBS의 선량비교 = Comparison of Doses of Single Scan PBS and Layered Rescanning PBS Using Moving Phantom in Proton Therapy
저자
김경태 ; 김선영 ; 김대웅 ; 김재원 ; 박지연 ; 전상민 ; Kim, Kyeong Tae ; Kim, Seon Yeong ; Kim, Dae Woong ; Kim, Jae Won ; Park, Ji Yeon ; Jeon, Sang Min 연구자관계분석
발행기관
학술지명
대한방사선치료학회지(The journal of the korean society for radiotherapeutic technology )
권호사항
발행연도
2019
작성언어
Korean
주제어
자료형태
학술저널
수록면
43-49(7쪽)
제공처
목 적: 움직이는 장기에 취약한 Pencil Beam Scanning(PBS)을 보완하기 위해 고안된 Layered Rescanning PBS 기법을 Moving Phantom에 적용하여 Single Scan PBS와 선량비교를 통해 Homogeneity를 비교해 본다. 대상 및 방법: Matrix X(IBA, Belgium)와 Moving Phantom(standard imaging, USA)을 이용하였다. 가상의 tumor $10{\times}10{\times}5cm$에 AP 방향에서 200 cGy의 선량을 조사하였다. 치료계획은 single scan PBS, rescan 4, 8, 12회 총 4가지로 하였고 각 치료계획별로 3번씩 반복 측정하였다. 측정 시 Moving Phantom의 호흡주기는 한 cycle당 4초로 설정 후 S-I 방향 움직임 2 cm으로 설정하였다. 추가로 beam on time을 측정하였다. 결 과: PTV 내에서 $D_{max}$의 평균값은 single scan, 4, 8, 12회 rescan 순서로 각각 $246.47{\pm}18.8cGy$, $223.43{\pm}8.92cGy$, $222.47{\pm}7.7cGy$, $213.9{\pm}6.11cGy$ $D_{min}$의 평균값은 각각 $165.53{\pm}4.32cGy$, $173.13{\pm}11.94cGy$, $184.13{\pm}8.04cGy$, $182.67{\pm}4.38cGy$으로 $D_{mean}$ $192.77{\pm}6.98cGy$, $196.7{\pm}4.01cGy$, $198.17{\pm}4.96cGy$, $195.77{\pm}3.15cGy$으로 측정되었다. 그리고 rescan 횟수가 늘어날수록 Homogeneity Index가 1에 가까워졌으며, beam on time은 평균 2분 15초, 3분 15초, 4분 30초, 5분 37초로 rescan 횟수가 증가할수록 치료시간이 증가되었다. 측정하는 과정에서 MU가 낮은 선량 layer에서는 설정한 rescan 횟수만큼 실제로 rescan하지 못하는 문제점이 발견되었다. 결 론: 장기 움직임이 있는 종양 치료 시 Layered Rescanning PBS을 적용했을 때 single scan PBS보다 균일한 선량분포를 확인할 수 있었다. 그리고 rescan 횟수가 증가할수록 균일한 선량분포를 보였다. single scan PBS와 12회 Layered rescanning 비교 시 HI 수치가 0.32 향상되었다. 추후 연구를 통하여 호흡동조 방사선치료가 불가능환자에게 적용이 가능할 것으로 사료된다.
더보기Purpose : We apply the Layered Rescanning PBS designed to complement the Pencil Beam Scanning(PBS), which is vulnerable to moving organs with the Moving Phantom, and compare the homogeneity with the single scan PBS. Methods and materials: Matrix X (IBA, Belgium) and Moving Phantom (standard imaging, USA) were used. A dose of 200 cGy was measured in the AP direction on a hypothetical tumor $10{\times}10{\times}5cm$. The plan type was planned as 4 kinds of sinlge scan PBS, rescan number 4, 8, 12 times. Were measured three times for each types. During the measurement, the respiratory cycle of the Moving Phantom was generally set to 4 seconds per cycle, and the movement radius in the S-I direction was set to 2 cm. In addition, beam on time was measured. Results : The mean values of $D_{max}$ in the PTV were $246.47{\pm}18.8cGy$, $223.43{\pm}8.92cGy$, and $222.47{\pm}7.7cGy$, $213.9{\pm}6.11cGy$ and the mean values of $D_{min}$ were $165.53{\pm}4.32cGy$, $173.13{\pm}11.94cGy$, $184.13{\pm}8.04cGy$, $182.67{\pm}4.38cGy$ and the mean values of $D_{mean}$ $192.77{\pm}6.98cGy$, $196.7{\pm}4.01cGy$, $198.17{\pm}4.96cGy$, $195.77{\pm}3.15cGy$ respectively. As the number of rescanning increased, the Homogeneity Index converged to 1. The beam on time was measured as 2:15, 3:15, 4:30, 5:37 on average. In the measurement process, in the low dose layer of the MU, the problem was found that it was not rescanned as many times as the set number of rescan. Conclusions : In the treatment of tumors with long-term movements, the application of layered rescanning PBS showed a more uniform dose distribution than single scan PBS. And as the number of rescan increase, the distribution of homogeneity is uniform. Compared with single scan plan and 12 rescan plan, HI value was improved by 0.32. Further studies are expected to be applicable to patients who can not be treated with respiratory synchronous radiation therapy.
더보기서지정보 내보내기(Export)
닫기소장기관 정보
닫기권호소장정보
닫기오류접수
닫기오류 접수 확인
닫기음성서비스 신청
닫기음성서비스 신청 확인
닫기이용약관
닫기학술연구정보서비스 이용약관 (2017년 1월 1일 ~ 현재 적용)
학술연구정보서비스(이하 RISS)는 정보주체의 자유와 권리 보호를 위해 「개인정보 보호법」 및 관계 법령이 정한 바를 준수하여, 적법하게 개인정보를 처리하고 안전하게 관리하고 있습니다. 이에 「개인정보 보호법」 제30조에 따라 정보주체에게 개인정보 처리에 관한 절차 및 기준을 안내하고, 이와 관련한 고충을 신속하고 원활하게 처리할 수 있도록 하기 위하여 다음과 같이 개인정보 처리방침을 수립·공개합니다.
주요 개인정보 처리 표시(라벨링)
목 차
3년
또는 회원탈퇴시까지5년
(「전자상거래 등에서의 소비자보호에 관한3년
(「전자상거래 등에서의 소비자보호에 관한2년
이상(개인정보보호위원회 : 개인정보의 안전성 확보조치 기준)개인정보파일의 명칭 | 운영근거 / 처리목적 | 개인정보파일에 기록되는 개인정보의 항목 | 보유기간 | |
---|---|---|---|---|
학술연구정보서비스 이용자 가입정보 파일 | 한국교육학술정보원법 | 필수 | ID, 비밀번호, 성명, 생년월일, 신분(직업구분), 이메일, 소속분야, 웹진메일 수신동의 여부 | 3년 또는 탈퇴시 |
선택 | 소속기관명, 소속도서관명, 학과/부서명, 학번/직원번호, 휴대전화, 주소 |
구분 | 담당자 | 연락처 |
---|---|---|
KERIS 개인정보 보호책임자 | 정보보호본부 김태우 | - 이메일 : lsy@keris.or.kr - 전화번호 : 053-714-0439 - 팩스번호 : 053-714-0195 |
KERIS 개인정보 보호담당자 | 개인정보보호부 이상엽 | |
RISS 개인정보 보호책임자 | 대학학술본부 장금연 | - 이메일 : giltizen@keris.or.kr - 전화번호 : 053-714-0149 - 팩스번호 : 053-714-0194 |
RISS 개인정보 보호담당자 | 학술진흥부 길원진 |
자동로그아웃 안내
닫기인증오류 안내
닫기귀하께서는 휴면계정 전환 후 1년동안 회원정보 수집 및 이용에 대한
재동의를 하지 않으신 관계로 개인정보가 삭제되었습니다.
(참조 : RISS 이용약관 및 개인정보처리방침)
신규회원으로 가입하여 이용 부탁 드리며, 추가 문의는 고객센터로 연락 바랍니다.
- 기존 아이디 재사용 불가
휴면계정 안내
RISS는 [표준개인정보 보호지침]에 따라 2년을 주기로 개인정보 수집·이용에 관하여 (재)동의를 받고 있으며, (재)동의를 하지 않을 경우, 휴면계정으로 전환됩니다.
(※ 휴면계정은 원문이용 및 복사/대출 서비스를 이용할 수 없습니다.)
휴면계정으로 전환된 후 1년간 회원정보 수집·이용에 대한 재동의를 하지 않을 경우, RISS에서 자동탈퇴 및 개인정보가 삭제처리 됩니다.
고객센터 1599-3122
ARS번호+1번(회원가입 및 정보수정)