석유화학 산단지역의 악취성 VOCs 물질 배출 특성 = Emission Characteristics of Odorous Volatile Organic Compounds in Petrochemical Industrial Complex
This study estimated the emission characteristics of odorous volatiles organic compounds (VOCs) from major 7 emission facilities by industrial classification in Yeosu petrochemical industrial complex. This study investigated terminal emission facilities (Inlet and outlet) in the industrial plant area, the plant boundary area and Samil-dong which has many civil appeal for an offensive odor to grasp VOCs concentration in ambient air of the plant boundary area and civil appeal area from May, 2002 to December, 2004, besides. VOCs were sampled 6 L using silicocan canisters and toluene, xylene and styrene which are known as odorous VOCs were analyzed by cryogenic preconcentration system and GC/MS. The removal efficiency of emission facilities in the industrial plant area for odor showed 96.5% of wet scrubber, 89.5% of RTO and 86.0% of RCO. The concentration of odorous VOCs at the plant limits area in 2003 were higher than 2002. The reason was guessed that toluene of high concentration emitted from terminal emission facilities in the industrial plant area influenced on ambient air at the plant boundary area. The concentration of odorous VOCs in ambient air at Samil-dong were decreasing from 1995 to 2001, but the concentration of toluene sharply increased from 2002. The reason was presumed that VOCs emission increased due to expansion of Yeosu petrochemical industrial complex and removal efficiency of terminal emission facilities dropped due to outworn equipments for VOCs prevent.
더보기본 연구는 여수석유화학산단 내 일부 업종별 규모가 큰 대표적인 7개 사업장들의 배출시설에 대하여 악취성 VOC 물질 배출특성을 평가하였다. 또한 사업장 부지경계지역 및 민원지역의 대기 중 VOC 농도 경향을 파악하고자 2002년 5월부터 2004년 12월까지 사업장내 최종 배출시설(유입구 및 배출구, inlet and outlet), 사업장 부지경계지점과 악취민원 제기가 많은 삼일동 지점에 대하여 조사하였다. VOCs 시료는 silicocan canister 6 L로 채취하였으며, 저온농축장치(cryogenic preconcentration system)와 GC/MS를 이용하여 분석하였으며, 조사항목은 악취성 VOC로 알려진 3개 항목(toluene, xylene, styrene)을 분석하였다. 연구결과는 다음과 같으며, 사업장내 배출시설의 악취 제거효율(removal efficiency)은 흡수탑 (96.5%) > RTO (89.5%) > RCO (86.0%) 순으로 우수한 것으로 나타났다. 사업장 부지경계지점은 2002년에 비해 2003년의 악취성 VOC 농도가 상승한 것으로 조사되었다. 이는 사업장내 최종 배출시설 자체에서 toluene 물질이 높은 농도로 배출되어 사업장 부지경계지역의 대기 중 농도에 영향을 미친 것으로 생각된다. 민원지역인 삼일동 지점의 대기 중 악취성 VOC 농도는 1995년부터 2001년까지 점차 감소하다가 특히 toluene 성분은 2002년부터 다시 급격히 증가하는 경향을 보였다. 이는 여수산단지역 확장으로 인한 사업장내 VOC 물질 배출 증가와 10여년 전에 설치된 VOC 방지시설의 노후로 인한 방지효율 저감에 의한 영향으로 생각된다.
더보기분석정보
연월일 | 이력구분 | 이력상세 | 등재구분 |
---|---|---|---|
2027 | 평가예정 | 재인증평가 신청대상 (재인증) | |
2021-01-01 | 평가 | 등재학술지 유지 (재인증) | KCI등재 |
2018-01-01 | 평가 | 등재학술지 유지 (등재유지) | KCI등재 |
2015-01-01 | 평가 | 등재학술지 선정 (계속평가) | KCI등재 |
2014-03-31 | 학술지명변경 | 한글명 : 한국냄새환경학회지 -> 실내환경 및 냄새 학회지외국어명 : Journal of Korean Society of Odor Research and Engineering -> Journal of Odor and Indoor Environment | KCI후보 |
2013-01-01 | 평가 | 등재후보 1차 FAIL (등재후보1차) | KCI후보 |
2012-12-24 | 학술지명변경 | 외국어명 : Korean Journal of Odor Research and Engineering -> Journal of Korean Society of Odor Research and Engineering | KCI후보 |
2012-01-01 | 평가 | 등재후보학술지 유지 (기타) | KCI후보 |
2011-01-01 | 평가 | 등재후보학술지 유지 (등재후보1차) | KCI후보 |
2010-01-01 | 평가 | 등재후보학술지 유지 (등재후보1차) | KCI후보 |
2009-01-01 | 평가 | 등재후보학술지 유지 (등재후보1차) | KCI후보 |
2007-01-01 | 평가 | 등재후보학술지 선정 (신규평가) | KCI후보 |
기준연도 | WOS-KCI 통합IF(2년) | KCIF(2년) | KCIF(3년) |
---|---|---|---|
2016 | 0.45 | 0.45 | 0.42 |
KCIF(4년) | KCIF(5년) | 중심성지수(3년) | 즉시성지수 |
0.45 | 0.42 | 0.554 | 0.11 |
서지정보 내보내기(Export)
닫기소장기관 정보
닫기권호소장정보
닫기오류접수
닫기오류 접수 확인
닫기음성서비스 신청
닫기음성서비스 신청 확인
닫기이용약관
닫기학술연구정보서비스 이용약관 (2017년 1월 1일 ~ 현재 적용)
학술연구정보서비스(이하 RISS)는 정보주체의 자유와 권리 보호를 위해 「개인정보 보호법」 및 관계 법령이 정한 바를 준수하여, 적법하게 개인정보를 처리하고 안전하게 관리하고 있습니다. 이에 「개인정보 보호법」 제30조에 따라 정보주체에게 개인정보 처리에 관한 절차 및 기준을 안내하고, 이와 관련한 고충을 신속하고 원활하게 처리할 수 있도록 하기 위하여 다음과 같이 개인정보 처리방침을 수립·공개합니다.
주요 개인정보 처리 표시(라벨링)
목 차
3년
또는 회원탈퇴시까지5년
(「전자상거래 등에서의 소비자보호에 관한3년
(「전자상거래 등에서의 소비자보호에 관한2년
이상(개인정보보호위원회 : 개인정보의 안전성 확보조치 기준)개인정보파일의 명칭 | 운영근거 / 처리목적 | 개인정보파일에 기록되는 개인정보의 항목 | 보유기간 | |
---|---|---|---|---|
학술연구정보서비스 이용자 가입정보 파일 | 한국교육학술정보원법 | 필수 | ID, 비밀번호, 성명, 생년월일, 신분(직업구분), 이메일, 소속분야, 웹진메일 수신동의 여부 | 3년 또는 탈퇴시 |
선택 | 소속기관명, 소속도서관명, 학과/부서명, 학번/직원번호, 휴대전화, 주소 |
구분 | 담당자 | 연락처 |
---|---|---|
KERIS 개인정보 보호책임자 | 정보보호본부 김태우 | - 이메일 : lsy@keris.or.kr - 전화번호 : 053-714-0439 - 팩스번호 : 053-714-0195 |
KERIS 개인정보 보호담당자 | 개인정보보호부 이상엽 | |
RISS 개인정보 보호책임자 | 대학학술본부 장금연 | - 이메일 : giltizen@keris.or.kr - 전화번호 : 053-714-0149 - 팩스번호 : 053-714-0194 |
RISS 개인정보 보호담당자 | 학술진흥부 길원진 |
자동로그아웃 안내
닫기인증오류 안내
닫기귀하께서는 휴면계정 전환 후 1년동안 회원정보 수집 및 이용에 대한
재동의를 하지 않으신 관계로 개인정보가 삭제되었습니다.
(참조 : RISS 이용약관 및 개인정보처리방침)
신규회원으로 가입하여 이용 부탁 드리며, 추가 문의는 고객센터로 연락 바랍니다.
- 기존 아이디 재사용 불가
휴면계정 안내
RISS는 [표준개인정보 보호지침]에 따라 2년을 주기로 개인정보 수집·이용에 관하여 (재)동의를 받고 있으며, (재)동의를 하지 않을 경우, 휴면계정으로 전환됩니다.
(※ 휴면계정은 원문이용 및 복사/대출 서비스를 이용할 수 없습니다.)
휴면계정으로 전환된 후 1년간 회원정보 수집·이용에 대한 재동의를 하지 않을 경우, RISS에서 자동탈퇴 및 개인정보가 삭제처리 됩니다.
고객센터 1599-3122
ARS번호+1번(회원가입 및 정보수정)