KCI등재후보
Dual source CT 장비의 high pitch(flash) chest pain protocol을 이용한 dissection검사의 유용성 평가 = Assessment for the usefulness of dissection using the high pitch chest pain protocol of dual source CT
저자
박찬혁(Chan Hyeok Park) ; 손성실(Seong Sil Son) ; 현진경(Jin Gyeong Hyeon) ; 이예나(Ye Na Lee) ; 강동원(Dong Won Kang)
발행기관
학술지명
대한CT영상기술학회지(Journal of Korean society of cumputed tomographic technology)
권호사항
발행연도
2011
작성언어
-주제어
KDC
512.151
등재정보
KCI등재후보
자료형태
학술저널
발행기관 URL
수록면
117-125(9쪽)
제공처
목 적 Dual source CT 장비의 high pitch chest pain protocol을 이용하여 ECG gating함으로써 ascending aorta의 blurring을 감소시키고, dissection의 coronary artery 침범유무의 확인과 동시에 환자의 피폭선량을 감소시키고자 하였다. 대상 및 방법 2010년 1월부터 2010년 07월까지 본원을 방문한 환자를 대상으로 Definition Flash, Definition AS+장비와 AAPM 팬텀을 이용하여 dissection 검사자의 CTDI값을 비교분석하였고 Dissection의 전반적인 판독유무를 관찰하였다. 첫 번째 비교대상으로는 ECG gating과 non-ECG gating방법으로 검사하여 Aortic root images을 비교하는 것이다. high pitch(flash) chest pain protocol방법으로 검사한 영상들과 기존의 방식으로 ECG gating 없이 검사한 환자의 Aortic root image의 판독유무를 관찰하였다. 그 두 번째로 high pitch(flash) chest pain protocol로 ECG gating한 방법과 일반적인 chest pain protocol로 ECG gating하여 동일한 AAPM팬텀을 scan 하였다. 이렇게 획득된 팬텀영상을 가지고 동일한 image quality를 가지는 parameter 값을조절하고 Dose량, 즉 CTDI값을 비교해 보았다. 결 과 ECG gating을 함으로 해서 ascending aorta의 blurring은 기존의 Non-ECG gating 검사방법보다 월등하게 감소시킬 수 있었으며 Aortic root의 image quality는 향상되었다. Chest pain protocol과 Flash chest pain protocol을 비교했을 때 noise, uniformity, high contrast resolution의 차이를 보이지 않는 parametar 범위 내에서, high-pitch chest pain protocol로 검사하였을 때CTDI 값이 더욱 더 낮게 나왔으므로 dose reduction에 도이점이 있음을 알 수 있었다. 결 론 Dose reduction을 고려함에 있어 특히 관심의 대상이 되어 왔던 분야는 cardiac이었다. 이러한 cardiac분야의 dose reduction mode를 이용하여 dissection과 같은 진단분야에 응용하여 적용한다면 획기적인 피폭선량 감소 효과 뿐만 아니라 빠른진단과 함께 신속한 치료가 필요한 환자들에게 매우 중요한 검사방법이 될 것으로 사료된다.
더보기Ⅰ. Purpose It is to decrease motion artifacts of blurring on the image of the ascending aorta and to decline exposed dose. In addition, it is to confirm invasion of dissection on coronary artery. Ⅱ. Materials and Methods This study was gⅣen to a sample of patients visiting the hospital for dissection from January 2010 to July 2010. The CTDI and DLP values of the examination were compared and analyzed which were from AAPM scanned by Definition Flash and Definition AS+. Moreover, the image qualities of the ascending aorta were observed in a diagnostic point of view. Firstly, aortic root were compared on the images between ECG gating and Non-ECG gating. It is to observe the images of ascending aorta by ECG gated high pitch chest pain protocol against existing Non-ECG gated dissection protocol. Secondly CTDI and DLP values were compared between high pitch chest pain protocol and chest pain protocol. Both of them were ECG gated. AAPM was scanned in two methods. The parameters of both scan were adjusted to make the images to the same quality then the CTDI and DLP values were measured in both of the ways. Ⅲ. Results The method with ECG gating reduced motion artifacts of ascending aorta compared to non-ECG gating. Therefore, image quality of aortic root was developed. In the method of high-pitch chest pain protocol, CTDI and DLP were half smaⅡer than the values scanned by general chest pain protocol. Accordingly, it has also advantage in dose reduction. Ⅳ. Conclusion According to dose reduction, hot issue was about cardiac. So, various methods scanning cardiac for dose reduction has developed. Therefore, if these dose reduction modes are applied to something like dissection in diagnostic field, there wiⅡ be a positⅣe effect on dose reduction as weⅡ as fast diagnosis and treatment for many patients.
더보기서지정보 내보내기(Export)
닫기소장기관 정보
닫기권호소장정보
닫기오류접수
닫기오류 접수 확인
닫기음성서비스 신청
닫기음성서비스 신청 확인
닫기이용약관
닫기학술연구정보서비스 이용약관 (2017년 1월 1일 ~ 현재 적용)
학술연구정보서비스(이하 RISS)는 정보주체의 자유와 권리 보호를 위해 「개인정보 보호법」 및 관계 법령이 정한 바를 준수하여, 적법하게 개인정보를 처리하고 안전하게 관리하고 있습니다. 이에 「개인정보 보호법」 제30조에 따라 정보주체에게 개인정보 처리에 관한 절차 및 기준을 안내하고, 이와 관련한 고충을 신속하고 원활하게 처리할 수 있도록 하기 위하여 다음과 같이 개인정보 처리방침을 수립·공개합니다.
주요 개인정보 처리 표시(라벨링)
목 차
3년
또는 회원탈퇴시까지5년
(「전자상거래 등에서의 소비자보호에 관한3년
(「전자상거래 등에서의 소비자보호에 관한2년
이상(개인정보보호위원회 : 개인정보의 안전성 확보조치 기준)개인정보파일의 명칭 | 운영근거 / 처리목적 | 개인정보파일에 기록되는 개인정보의 항목 | 보유기간 | |
---|---|---|---|---|
학술연구정보서비스 이용자 가입정보 파일 | 한국교육학술정보원법 | 필수 | ID, 비밀번호, 성명, 생년월일, 신분(직업구분), 이메일, 소속분야, 웹진메일 수신동의 여부 | 3년 또는 탈퇴시 |
선택 | 소속기관명, 소속도서관명, 학과/부서명, 학번/직원번호, 휴대전화, 주소 |
구분 | 담당자 | 연락처 |
---|---|---|
KERIS 개인정보 보호책임자 | 정보보호본부 김태우 | - 이메일 : lsy@keris.or.kr - 전화번호 : 053-714-0439 - 팩스번호 : 053-714-0195 |
KERIS 개인정보 보호담당자 | 개인정보보호부 이상엽 | |
RISS 개인정보 보호책임자 | 대학학술본부 장금연 | - 이메일 : giltizen@keris.or.kr - 전화번호 : 053-714-0149 - 팩스번호 : 053-714-0194 |
RISS 개인정보 보호담당자 | 학술진흥부 길원진 |
자동로그아웃 안내
닫기인증오류 안내
닫기귀하께서는 휴면계정 전환 후 1년동안 회원정보 수집 및 이용에 대한
재동의를 하지 않으신 관계로 개인정보가 삭제되었습니다.
(참조 : RISS 이용약관 및 개인정보처리방침)
신규회원으로 가입하여 이용 부탁 드리며, 추가 문의는 고객센터로 연락 바랍니다.
- 기존 아이디 재사용 불가
휴면계정 안내
RISS는 [표준개인정보 보호지침]에 따라 2년을 주기로 개인정보 수집·이용에 관하여 (재)동의를 받고 있으며, (재)동의를 하지 않을 경우, 휴면계정으로 전환됩니다.
(※ 휴면계정은 원문이용 및 복사/대출 서비스를 이용할 수 없습니다.)
휴면계정으로 전환된 후 1년간 회원정보 수집·이용에 대한 재동의를 하지 않을 경우, RISS에서 자동탈퇴 및 개인정보가 삭제처리 됩니다.
고객센터 1599-3122
ARS번호+1번(회원가입 및 정보수정)