KCI등재
SCIE
SCOPUS
Thermal Model Correlation and Validation of a 6U Nanosatellite with Multiple Payloads
Due to the miniaturization of satellite components and advantages of low costs and short periods of development, nanosatellites are rapidly being developed to operate a wide variety of missions beyond only education purposes, such as Earth observation, relay communication, scientific objective, and even space exploration. As the role of nanosatellite grew, the reliability of nanosat’s thermal subsystem is also becoming very important to successfully carry it out. However, there is rare to find a research on thermal design reliability validation of 6U nanosatellite with increasingly large, diverse, and complex missions. Since reliability of satellite thermal design can be evaluated by on-orbit thermal analysis with the thermal mathematical model, more accurate analysis results can be obtained through more accurate thermal model. In addition, the thermal model can be improved by process of model correlation. The process begins with conducting thermal vacuum test (TVT) and is a flow that reduces thermal uncertainties by comparing the test results with analytical results. Nanosatellite systems are thermally closely connected within a limited space, so that thermal design cannot proceed conclusively for each subsystem and module. Therefore, it should always be done from a system perspective when thermal model of nanosatellite with multiple payloads is correlated especially. In this paper, we introduced a 6U nanosatellite of SNIPE (Small scale magNetospheric and Ionospheric Plasma Experiment) Mission that developing from KARI (Korea Aerospace Research Institute) and KASI (Korea Astronomy and Space Science Institute) for the near-Earth space environment scientific missions. For the successful mission operation, we conducted TVT for simulating space thermal vacuum environment to verify thermal design of thermal control system in the worst case. In addition, thermal model correlation of SNIPE nanosatellite was conducted through the TVT results with not only system level but each component and module. Based on the updated thermal model via the model correlation, we performed on-orbit thermal analysis to demonstrate the validity of thermal model and thermal design of the system level. As a result, we have confirmed that all components of the SNIPE nanosat satisfy the allowable temperature limit, which has correlated the thermal model and validated the thermal design successfully. The performed process can be applied to 6U or bigger nanosatellite for the objectives of practical missions or technology demonstrations that need the validity of thermal design and improvement of thermal model through the test and analysis. Therefore, this study is expected to contribute to the successful performance of the more complex and sophisticated nanosatellite missions to be developed.
더보기분석정보
연월일 | 이력구분 | 이력상세 | 등재구분 |
---|---|---|---|
2023 | 평가예정 | 해외DB학술지평가 신청대상 (해외등재 학술지 평가) | |
2020-01-01 | 평가 | 등재학술지 유지 (해외등재 학술지 평가) | KCI등재 |
2013-10-01 | 평가 | 등재학술지 선정 (기타) | KCI등재 |
2011-01-01 | 평가 | 등재후보학술지 선정 (기타) | KCI후보 |
기준연도 | WOS-KCI 통합IF(2년) | KCIF(2년) | KCIF(3년) |
---|---|---|---|
2016 | 0.37 | 0.2 | 0.3 |
KCIF(4년) | KCIF(5년) | 중심성지수(3년) | 즉시성지수 |
0.26 | 0.24 | 0.394 | 0.03 |
서지정보 내보내기(Export)
닫기소장기관 정보
닫기권호소장정보
닫기오류접수
닫기오류 접수 확인
닫기음성서비스 신청
닫기음성서비스 신청 확인
닫기이용약관
닫기학술연구정보서비스 이용약관 (2017년 1월 1일 ~ 현재 적용)
학술연구정보서비스(이하 RISS)는 정보주체의 자유와 권리 보호를 위해 「개인정보 보호법」 및 관계 법령이 정한 바를 준수하여, 적법하게 개인정보를 처리하고 안전하게 관리하고 있습니다. 이에 「개인정보 보호법」 제30조에 따라 정보주체에게 개인정보 처리에 관한 절차 및 기준을 안내하고, 이와 관련한 고충을 신속하고 원활하게 처리할 수 있도록 하기 위하여 다음과 같이 개인정보 처리방침을 수립·공개합니다.
주요 개인정보 처리 표시(라벨링)
목 차
3년
또는 회원탈퇴시까지5년
(「전자상거래 등에서의 소비자보호에 관한3년
(「전자상거래 등에서의 소비자보호에 관한2년
이상(개인정보보호위원회 : 개인정보의 안전성 확보조치 기준)개인정보파일의 명칭 | 운영근거 / 처리목적 | 개인정보파일에 기록되는 개인정보의 항목 | 보유기간 | |
---|---|---|---|---|
학술연구정보서비스 이용자 가입정보 파일 | 한국교육학술정보원법 | 필수 | ID, 비밀번호, 성명, 생년월일, 신분(직업구분), 이메일, 소속분야, 웹진메일 수신동의 여부 | 3년 또는 탈퇴시 |
선택 | 소속기관명, 소속도서관명, 학과/부서명, 학번/직원번호, 휴대전화, 주소 |
구분 | 담당자 | 연락처 |
---|---|---|
KERIS 개인정보 보호책임자 | 정보보호본부 김태우 | - 이메일 : lsy@keris.or.kr - 전화번호 : 053-714-0439 - 팩스번호 : 053-714-0195 |
KERIS 개인정보 보호담당자 | 개인정보보호부 이상엽 | |
RISS 개인정보 보호책임자 | 대학학술본부 장금연 | - 이메일 : giltizen@keris.or.kr - 전화번호 : 053-714-0149 - 팩스번호 : 053-714-0194 |
RISS 개인정보 보호담당자 | 학술진흥부 길원진 |
자동로그아웃 안내
닫기인증오류 안내
닫기귀하께서는 휴면계정 전환 후 1년동안 회원정보 수집 및 이용에 대한
재동의를 하지 않으신 관계로 개인정보가 삭제되었습니다.
(참조 : RISS 이용약관 및 개인정보처리방침)
신규회원으로 가입하여 이용 부탁 드리며, 추가 문의는 고객센터로 연락 바랍니다.
- 기존 아이디 재사용 불가
휴면계정 안내
RISS는 [표준개인정보 보호지침]에 따라 2년을 주기로 개인정보 수집·이용에 관하여 (재)동의를 받고 있으며, (재)동의를 하지 않을 경우, 휴면계정으로 전환됩니다.
(※ 휴면계정은 원문이용 및 복사/대출 서비스를 이용할 수 없습니다.)
휴면계정으로 전환된 후 1년간 회원정보 수집·이용에 대한 재동의를 하지 않을 경우, RISS에서 자동탈퇴 및 개인정보가 삭제처리 됩니다.
고객센터 1599-3122
ARS번호+1번(회원가입 및 정보수정)