토모테라피 치료 시 Bodyfix System에서 진공압박에 따른 환자 위치잡이오차(Setup errors)의 평가 = Evaluation of Setup Errors for Tomotherapy Using Differently Applied Vacuum Compression with the Bodyfix Immobilization System
저자
정재홍 (가톨릭대학교) ; 조광환 (순천향대학교) ; 이정우 (건국대학교병원) ; 김민주 (가톨릭대학교) ; 임광채 (순천향대학교) ; 문성권 (순천향대학교) ; 김용호 (순천향대학교) ; 서태석 (가톨릭대학교) ; Jung, Jae-Hong ; Cho, Kwang-Hwan ; Lee, Jeong-Woo ; Kim, Min-Joo ; Lim, Kwang-Chae ; Moon, Seong-Kwon ; Kim, Yong-Ho ; Suh, Tae-Suk
발행기관
학술지명
권호사항
발행연도
2011
작성언어
Korean
주제어
등재정보
KCI등재
자료형태
학술저널
발행기관 URL
수록면
72-78(7쪽)
KCI 피인용횟수
0
제공처
본 연구의 목적은 토모테라피(Hi-ArtII, TomoTherapy, USA) 치료 시 Bodyfix system (Medical Intelligence, Ele-kta, Schwabmuchen, Germany)에서 진공압박(Vacuum compression)에 따라 환자 위치잡이오차(Patient's setup-errors)를 평가하고자 하였다. Bodyfix system와 진공압박을 적용한 토모테라피를 이용하여 치료를 시행한 흉복부 환자 21명을 선정하였으며, 모든 환자는 치료 전 촬영된 총 477개의 메가볼테이지 전산화단층촬영(Mega-voltage computed tomography, MVCT)영상을 얻었다. 이를 통하여 확인된 좌우방향(Medial-Lateral direction, ML), 앞뒤방향(Anterior-Posterior direction, AP), 상하방향(Superior-Inferior direction, SI)과 SI중심축 회전각(Rotational angle of SI axis direction, Roll)에 대한 오차를 기록하고, 분석하였다. 세 방향 및 Roll에 대한 상관관계와 진공압박 정도가 다르게 적용된 다섯 그룹에 대하여 setup-errors를 분석하기 위해 각각 Pearson's product-moment coefficient와 One-way ANOVA를 이용하여 통계적으로 분석하였다(p<0.05). 분석결과 Systematic errors의 평균은 AP에서 6.00 mm, 표준편차는 SI에서 5.95 mm로 큰 오차를 보였다. Random errors의 평균은 SI방향에서 4.72 mm로 큰 오차가 발생하였다. 관계분석에서는 상관계수가 ML-Roll과 AP-Vector는 0.485, 0.244이고, SI-Vector에서 관계가 제일 높았다(0.637). 또한, 진공압박 정도가 다르게 적용된 다섯 그룹(Pressure range: 30~70 mbar) 사이의 setup errors를 분석한 결과 ML, SI방향과 Roll에서 모두 p=0.00 (p<0.05)로써 유의한 차이를 보였으며, SI방향에서 진공압박에 따른 오차 평균은 40 mbar과 70 mbar그룹에서 4.78 mm, -0.74 mm였다. 본 연구에서는 진공압박과 setup-errors의 평가를 통계적으로 분석하였으며, 압박 정도에 따라 SI방향에서 setup-errors의 차이를 확인하였다. 최종적으로 setup-errors와 내부장기의 움직임을 고려하자면 Bodyfix system을 이용한 진공압박을 적용시 최소 50 mbar 이상을 사용해야 할 것이다. 본 연구결과를 토대로 진공압박의 정확성과 내부장기 및 종양의 움직임을 정량적으로 분석할 필요가 있다고 판단된다.
더보기The aim of this study is to evaluate the patient's setup errors in TomoTherapy (Hi-Art II, TomoTherapy, USA) Bodyfix system (Medical Intelligence, Ele-kta, Schwabmuchen, Germany) pressure in the vacuum compression, depending on and were evaluated. Bodyfix immobilization system and vacuum pressure was compression applied to the patients who received Tomotherapy thoracic and abdominal area, 21 patients were selected and TomoTehpay treatment total 477 of MVCT images were obtained. The translational (medial-lateral: ML, anterior-posterior: AP, superior-inferior: SI directions) and rolling were recorded and analyzed statistically. Using Pearson's product-moment coefficient and One-way ANOVA, the degree of correlation depending on the different vacuum pressure levels were statistically analyzed for setup errors from five groups (p<0.05). The largest average and standard deviation of systematic errors were 6.00, 5.95 mm in the AP and SI directions, respectively. The largest average of random errors were 4.72 mm in the SI directions. The correlation coefficients were 0.485, 0.244, and 0.637 for the ML-Roll, AP-Vector, and SI-Vector, respectively. SI-Vector direction showed the best relationship. In the results of the different degree of vacuum pressure in five groups (Pressure range: 30~70 mbar), the setup errors between the ML, SI in both directions and Roll p=0.00 (p<0.05) were shown significant differences. The average errors of SI direction in the vacuum pressure of 40 mbar and 70 mbar group were 4.78 mm and -0.74 mm, respectively. In this study, the correlation between the vacuum pressure and the setup-errors were statistically analyzed. The fact that setup-errors in SI direction is dependent in vacuum pressure considerly setup-errors and movement of interal organs was identified. Finally, setup-errors, and it, based on the movement of internal organs in Bodyfix system we should apply more than 50 mbar vacuum pressure. Based on the results of this study, it is suggested that accuracy of the vacuum pressure and the quantitative analysis of movement of internal organs and the tumor should be studied.
더보기분석정보
연월일 | 이력구분 | 이력상세 | 등재구분 |
---|---|---|---|
2024 | 평가예정 | 재인증평가 신청대상 (재인증) | |
2021-01-01 | 평가 | 등재학술지 선정 (계속평가) | KCI등재 |
2019-01-01 | 평가 | 등재후보학술지 선정 (신규평가) | KCI후보 |
2016-12-01 | 평가 | 등재후보 탈락 (계속평가) | |
2015-12-01 | 평가 | 등재후보로 하락 (기타) | KCI후보 |
2014-07-10 | 학술지명변경 | 외국어명 : Korean Journal of Medical Physics -> PROGRESS in MEDICAL PHYSICS | KCI등재 |
2011-01-01 | 평가 | 등재학술지 유지 (등재유지) | KCI등재 |
2009-01-01 | 평가 | 등재 1차 FAIL (등재유지) | KCI등재 |
2006-01-01 | 평가 | 등재학술지 선정 (등재후보2차) | KCI등재 |
2005-01-01 | 평가 | 등재후보 1차 PASS (등재후보1차) | KCI후보 |
2003-07-01 | 평가 | 등재후보학술지 선정 (신규평가) | KCI후보 |
서지정보 내보내기(Export)
닫기소장기관 정보
닫기권호소장정보
닫기오류접수
닫기오류 접수 확인
닫기음성서비스 신청
닫기음성서비스 신청 확인
닫기이용약관
닫기학술연구정보서비스 이용약관 (2017년 1월 1일 ~ 현재 적용)
학술연구정보서비스(이하 RISS)는 정보주체의 자유와 권리 보호를 위해 「개인정보 보호법」 및 관계 법령이 정한 바를 준수하여, 적법하게 개인정보를 처리하고 안전하게 관리하고 있습니다. 이에 「개인정보 보호법」 제30조에 따라 정보주체에게 개인정보 처리에 관한 절차 및 기준을 안내하고, 이와 관련한 고충을 신속하고 원활하게 처리할 수 있도록 하기 위하여 다음과 같이 개인정보 처리방침을 수립·공개합니다.
주요 개인정보 처리 표시(라벨링)
목 차
3년
또는 회원탈퇴시까지5년
(「전자상거래 등에서의 소비자보호에 관한3년
(「전자상거래 등에서의 소비자보호에 관한2년
이상(개인정보보호위원회 : 개인정보의 안전성 확보조치 기준)개인정보파일의 명칭 | 운영근거 / 처리목적 | 개인정보파일에 기록되는 개인정보의 항목 | 보유기간 | |
---|---|---|---|---|
학술연구정보서비스 이용자 가입정보 파일 | 한국교육학술정보원법 | 필수 | ID, 비밀번호, 성명, 생년월일, 신분(직업구분), 이메일, 소속분야, 웹진메일 수신동의 여부 | 3년 또는 탈퇴시 |
선택 | 소속기관명, 소속도서관명, 학과/부서명, 학번/직원번호, 휴대전화, 주소 |
구분 | 담당자 | 연락처 |
---|---|---|
KERIS 개인정보 보호책임자 | 정보보호본부 김태우 | - 이메일 : lsy@keris.or.kr - 전화번호 : 053-714-0439 - 팩스번호 : 053-714-0195 |
KERIS 개인정보 보호담당자 | 개인정보보호부 이상엽 | |
RISS 개인정보 보호책임자 | 대학학술본부 장금연 | - 이메일 : giltizen@keris.or.kr - 전화번호 : 053-714-0149 - 팩스번호 : 053-714-0194 |
RISS 개인정보 보호담당자 | 학술진흥부 길원진 |
자동로그아웃 안내
닫기인증오류 안내
닫기귀하께서는 휴면계정 전환 후 1년동안 회원정보 수집 및 이용에 대한
재동의를 하지 않으신 관계로 개인정보가 삭제되었습니다.
(참조 : RISS 이용약관 및 개인정보처리방침)
신규회원으로 가입하여 이용 부탁 드리며, 추가 문의는 고객센터로 연락 바랍니다.
- 기존 아이디 재사용 불가
휴면계정 안내
RISS는 [표준개인정보 보호지침]에 따라 2년을 주기로 개인정보 수집·이용에 관하여 (재)동의를 받고 있으며, (재)동의를 하지 않을 경우, 휴면계정으로 전환됩니다.
(※ 휴면계정은 원문이용 및 복사/대출 서비스를 이용할 수 없습니다.)
휴면계정으로 전환된 후 1년간 회원정보 수집·이용에 대한 재동의를 하지 않을 경우, RISS에서 자동탈퇴 및 개인정보가 삭제처리 됩니다.
고객센터 1599-3122
ARS번호+1번(회원가입 및 정보수정)