치과 Implant 보철 수복시 자연지대치와의 연결형태에 따른 응력분석의 유한요소법적 분석 = A STUDY ON THE FINITE ELEMENT ANALYSIS OF STRESSES INDUCED BY THE CONNECTION MODALITES BETWEEL NATURAL ABUTMENTS AND DENTAL IMPLANTS
저자
발행기관
학술지명
권호사항
발행연도
1992
작성언어
Korean
KDC
510.000
자료형태
학술저널
수록면
181-197(17쪽)
제공처
소장기관
Dental prosthodontics, of which primary objective is the rehabilitation of mastication, esthetice and phonetics etc. caused by the loss of teeth and their supporting structures, has a new vista in which the studies of making fixed or removable prosthesis by implanting artificial roots into jaw one are actively under progress.
In the early phase, osseo-integrated implants were mostly used for the treatment of fully edentulous patients byt recently various methods of rehabilitation partial edentulous jaws has been studied and are actually applied to the clinical use.
Clinicians have much interest in the connection modalities of the natural abutments and implants, and he fact which type of connection brings about the most favorable results is a very important question.
As a part of biomechanical study of biofunction, stress analysis using finite elements were applied to compare and analyse stress produced in adjacent bone tissue to the natural abutments and dental implants.
Experimental models have dental implants in partial edentulous areas in the lower arch, where 1st and 2nd molars were unilaterally lost. 4 finite models(free standing, rigid, semi-rigid, and telescopic connector) were designed. Load of 1.5Kg and 30Kg were applied to each experimental group respectively.
After the models were checked and results were calculated by the transformation procedures following results were obtained. The stress occuring along the interface of cortical bone and supporting structures of the abutments, and along the cancellous bone, were compared according to the model types.
1. In the free standing implant prosthesis, which is not connected to the natural abutment tooth, high stress distributions were observed in the distal third area of natural abutment apex, mesio-cervical area of 1st implant and in disto-cervical area of 2nd implant in all of experimental groups.
2. In the case of rigid and telescopic models of 3 unit bridge, using one natural abutment and one implant fixture, stress distribution and amount were similar in both group 1(1.5㎏) and group 2(30㎏). High stress distributions were observed in the mesio-apical third of natural abutment and cervical region of implant fixture.
3. In the semi-rigid model, high stress distributions were observed in the cervical region of natural abutment and cervical third of implant fixture in group 1.Stresses were more concentrated in implant fixtures. In group 2, high stress distributions were observed in the apical third of natural tooth and in the mesio-apical third and disto-middle third of implant fixtures. The stress was concentrated more from mesio-apical third to the disto-middle third in the implant fixture than natural abutment tooth.
4. In the cancellous bone under the interface of cortical bone, natural abutment and implant fixtrue, stresses were concentrated on underlyingapex of natural abutment tooth in free standing model. Stree distribution was high in disto-middle third of natural abutment in rigid and telescopic model, and it was relatively high in each underlying apex of natural abutment. In group 1 of semi-rigid model, high stress distributions were observed in the disto-middle third of abutment tooth and in the mesial surface of implant fixtures. Stress distributions were high in the disto-middle third natural abutment and mesial and apical region of implant fixtures in group 2.
5. Under the limits of elasticity, the pattern of stress distribution was almost unaffected by the differences in the load applied, but resultant stress amounts were affected by the magnitude in the forces applied.
서지정보 내보내기(Export)
닫기소장기관 정보
닫기권호소장정보
닫기오류접수
닫기오류 접수 확인
닫기음성서비스 신청
닫기음성서비스 신청 확인
닫기이용약관
닫기학술연구정보서비스 이용약관 (2017년 1월 1일 ~ 현재 적용)
학술연구정보서비스(이하 RISS)는 정보주체의 자유와 권리 보호를 위해 「개인정보 보호법」 및 관계 법령이 정한 바를 준수하여, 적법하게 개인정보를 처리하고 안전하게 관리하고 있습니다. 이에 「개인정보 보호법」 제30조에 따라 정보주체에게 개인정보 처리에 관한 절차 및 기준을 안내하고, 이와 관련한 고충을 신속하고 원활하게 처리할 수 있도록 하기 위하여 다음과 같이 개인정보 처리방침을 수립·공개합니다.
주요 개인정보 처리 표시(라벨링)
목 차
3년
또는 회원탈퇴시까지5년
(「전자상거래 등에서의 소비자보호에 관한3년
(「전자상거래 등에서의 소비자보호에 관한2년
이상(개인정보보호위원회 : 개인정보의 안전성 확보조치 기준)개인정보파일의 명칭 | 운영근거 / 처리목적 | 개인정보파일에 기록되는 개인정보의 항목 | 보유기간 | |
---|---|---|---|---|
학술연구정보서비스 이용자 가입정보 파일 | 한국교육학술정보원법 | 필수 | ID, 비밀번호, 성명, 생년월일, 신분(직업구분), 이메일, 소속분야, 웹진메일 수신동의 여부 | 3년 또는 탈퇴시 |
선택 | 소속기관명, 소속도서관명, 학과/부서명, 학번/직원번호, 휴대전화, 주소 |
구분 | 담당자 | 연락처 |
---|---|---|
KERIS 개인정보 보호책임자 | 정보보호본부 김태우 | - 이메일 : lsy@keris.or.kr - 전화번호 : 053-714-0439 - 팩스번호 : 053-714-0195 |
KERIS 개인정보 보호담당자 | 개인정보보호부 이상엽 | |
RISS 개인정보 보호책임자 | 대학학술본부 장금연 | - 이메일 : giltizen@keris.or.kr - 전화번호 : 053-714-0149 - 팩스번호 : 053-714-0194 |
RISS 개인정보 보호담당자 | 학술진흥부 길원진 |
자동로그아웃 안내
닫기인증오류 안내
닫기귀하께서는 휴면계정 전환 후 1년동안 회원정보 수집 및 이용에 대한
재동의를 하지 않으신 관계로 개인정보가 삭제되었습니다.
(참조 : RISS 이용약관 및 개인정보처리방침)
신규회원으로 가입하여 이용 부탁 드리며, 추가 문의는 고객센터로 연락 바랍니다.
- 기존 아이디 재사용 불가
휴면계정 안내
RISS는 [표준개인정보 보호지침]에 따라 2년을 주기로 개인정보 수집·이용에 관하여 (재)동의를 받고 있으며, (재)동의를 하지 않을 경우, 휴면계정으로 전환됩니다.
(※ 휴면계정은 원문이용 및 복사/대출 서비스를 이용할 수 없습니다.)
휴면계정으로 전환된 후 1년간 회원정보 수집·이용에 대한 재동의를 하지 않을 경우, RISS에서 자동탈퇴 및 개인정보가 삭제처리 됩니다.
고객센터 1599-3122
ARS번호+1번(회원가입 및 정보수정)