SCOPUS
SCIE
Buoyant jet and two-phase jet-plume modeling for application to large water pools
저자
발행기관
학술지명
권호사항
발행연도
2011
작성언어
-등재정보
SCOPUS,SCIE
자료형태
학술저널
수록면
1667-1700(34쪽)
제공처
<P><B>Highlights</B></P><P>► A two-phase jet-plume model was developed to predict pool thermal response, pool surface temperature and consequently the pool cover gas pressure in enclosed spaces such as nuclear reactor wetwell. ► The jet-plume half-width, centerline velocity and temperature along the axis defining the plume's trajectory were solved as variables along the path. ► The pool surface temperature prediction is comparable to experimental data within 0.5°C.</P> <P><B>Abstract</B></P><P>Models of a single-phase liquid-into-liquid buoyant jet and a two-phase vapor-into-liquid turbulent jet-plume injected in horizontal orientation were developed for analyzing the dynamics of the mixing characteristics and thermal response for shallow submergence of the source in large pools. These models were developed from the Reynolds averaged Navier–Stokes equations in the cylindrical system for steady axisymmetric flow and incorporated the integral plume theory. The bases for the general assumptions such as self-similarity and use of Gaussian profiles to represent the velocity field across the effluent cross-section are examined. Subroutines were developed to reproduce the governing differential equations formulated from the continuity, momentum and conservation of buoyancy or energy equations which treats the jet-plume's half-width, velocity and temperature as variables and seek solutions of these variables along the jet-plume trajectory. Information on empirical closure relations obtained from experimental data such as the coefficient-of-entrainment, bubble slip velocity, momentum amplification factor, and plume spread-ratios for buoyancy and density-defect which are available for adiabatic cases were applied to the case of steam-into-water. Solutions were obtained without cross-flow in a linearly stratified ambient and then with cross-flow in a homogeneously mixed ambient for the single-phase formulation that represents a complete condensation scenario of a buoyant jet. The model was finally extended to the turbulent two-phase jet-plume case and the results were compared to available jet-plume pool condensation data. The analysis and results proved to be comparable to experimental data in predicting the pool surface temperature to within 0.5°C, however, temperature fluctuations along the jet-plume path were not adequately captured by the model since an oscillating input component was not incorporated in the model formulation; indeed the pool surface temperature proved to be of higher importance, which was adequately captured by the model.</P>
더보기서지정보 내보내기(Export)
닫기소장기관 정보
닫기권호소장정보
닫기오류접수
닫기오류 접수 확인
닫기음성서비스 신청
닫기음성서비스 신청 확인
닫기이용약관
닫기학술연구정보서비스 이용약관 (2017년 1월 1일 ~ 현재 적용)
학술연구정보서비스(이하 RISS)는 정보주체의 자유와 권리 보호를 위해 「개인정보 보호법」 및 관계 법령이 정한 바를 준수하여, 적법하게 개인정보를 처리하고 안전하게 관리하고 있습니다. 이에 「개인정보 보호법」 제30조에 따라 정보주체에게 개인정보 처리에 관한 절차 및 기준을 안내하고, 이와 관련한 고충을 신속하고 원활하게 처리할 수 있도록 하기 위하여 다음과 같이 개인정보 처리방침을 수립·공개합니다.
주요 개인정보 처리 표시(라벨링)
목 차
3년
또는 회원탈퇴시까지5년
(「전자상거래 등에서의 소비자보호에 관한3년
(「전자상거래 등에서의 소비자보호에 관한2년
이상(개인정보보호위원회 : 개인정보의 안전성 확보조치 기준)개인정보파일의 명칭 | 운영근거 / 처리목적 | 개인정보파일에 기록되는 개인정보의 항목 | 보유기간 | |
---|---|---|---|---|
학술연구정보서비스 이용자 가입정보 파일 | 한국교육학술정보원법 | 필수 | ID, 비밀번호, 성명, 생년월일, 신분(직업구분), 이메일, 소속분야, 웹진메일 수신동의 여부 | 3년 또는 탈퇴시 |
선택 | 소속기관명, 소속도서관명, 학과/부서명, 학번/직원번호, 휴대전화, 주소 |
구분 | 담당자 | 연락처 |
---|---|---|
KERIS 개인정보 보호책임자 | 정보보호본부 김태우 | - 이메일 : lsy@keris.or.kr - 전화번호 : 053-714-0439 - 팩스번호 : 053-714-0195 |
KERIS 개인정보 보호담당자 | 개인정보보호부 이상엽 | |
RISS 개인정보 보호책임자 | 대학학술본부 장금연 | - 이메일 : giltizen@keris.or.kr - 전화번호 : 053-714-0149 - 팩스번호 : 053-714-0194 |
RISS 개인정보 보호담당자 | 학술진흥부 길원진 |
자동로그아웃 안내
닫기인증오류 안내
닫기귀하께서는 휴면계정 전환 후 1년동안 회원정보 수집 및 이용에 대한
재동의를 하지 않으신 관계로 개인정보가 삭제되었습니다.
(참조 : RISS 이용약관 및 개인정보처리방침)
신규회원으로 가입하여 이용 부탁 드리며, 추가 문의는 고객센터로 연락 바랍니다.
- 기존 아이디 재사용 불가
휴면계정 안내
RISS는 [표준개인정보 보호지침]에 따라 2년을 주기로 개인정보 수집·이용에 관하여 (재)동의를 받고 있으며, (재)동의를 하지 않을 경우, 휴면계정으로 전환됩니다.
(※ 휴면계정은 원문이용 및 복사/대출 서비스를 이용할 수 없습니다.)
휴면계정으로 전환된 후 1년간 회원정보 수집·이용에 대한 재동의를 하지 않을 경우, RISS에서 자동탈퇴 및 개인정보가 삭제처리 됩니다.
고객센터 1599-3122
ARS번호+1번(회원가입 및 정보수정)