Purpose
Nowadays the breast cancer is one of the most important cause of female cancer attack rate in Korea due to many reasons of changes of dietary, variations of female hormone, diversities of lactation and so on. To diagnose this disease, mommography and breast sono graphy are universally accepted but additionally breast MRI and breast CT tests are the most prevalent treats recently.
First, Breast CT test allows us to figure out accurate lesions using reorganized 3D(three dementional methods) before operations and make a thorough examination for the presence of changes including axial image. Moreover it can be found out shapes of lesion, changes of lymph node and enhancement pattern. Second, it makes cut down shortcomings of previous CT tests because of scanning with minimum radiation exposure level.
Subjects and Methods
From jan. 2003 to dee. 2004 we designated 55 patients from commitments who were suffering from breast cancers through tests about mammogarphy, breast sono graphy, breast biopsy.
With Breast CT test, patients need to take a position with PRO, LPO which contacts with test strips and then put hands up over one’s head. Finally they are injected contrast materials. we have a scan for 90 sec. after infusion of them. And on passing away 300 sec., we also scan in order to identify states that are washed out of blood vessels. Entire amount of contrast materials is 130ml and similar to amounts took use of common CT tests as 3ml per second.
Phantoms are used with 4 slice MDCT as a test methods about a permissible radiation exposure level. we measured permissible radiation exposure level in first scanning at 0 o’clock and 8 o’clock and made them calculate in terms of CTDI.
Used materials
• 4 slice MDCTSomatom Volume Zoom(Siemens Medical Systems, Germany)
• Auto injector-Envision CT (Medrad)
• Contrast Media- non-ionic contrast. media Ultravist 370(lopromide, Schering)
• Workstation-Rapidia(INFINIT)
• CT ionization chamber
• Radiation dose phantom
• Electrometer (reader equipment)
Results
Lesions(malignant tumor) are 30HU in Pre-CE, 89.7HU IN 90sec-delay, 77.2HU in 300sec-delay in accordance with contrast enhancements and have fixed rate. CTDIDLP levels for such a test are distinguished such as breast CT 297mG, low dose CT 324mGy, chest CT 1206mGy. And breast CT test is the lowest or similar level.
Consequences
Breast tests which didn’t accepted in the past due to a great deal of dose, have extreme resolving power thanks to a development of MDCT(multi detecter computed tomography) and make resolving power be minimized and reduce test period. It allows us figure out lesions and give a hand while diagnosing additional lesion defections. Malignant tumors are identified through a pattern as contrast enhancements and help operation methods to be varied. In addition, though using reorganized 3D(three dementional methods), sham plans before operation can be available because we are able to see the whole shapes of breast, the appearances of blood supply and place of lymph node in 3D not just one section.
As women, their breasts are so sensitive and delicate that we can call them as “women’s pride”. With current medicine, we should take a consideration so that patients can spend their remaining in quality. In order to make a diagnosis, acquiring superior image quality is the important thing the society is confronted with.
서지정보 내보내기(Export)
닫기소장기관 정보
닫기권호소장정보
닫기오류접수
닫기오류 접수 확인
닫기음성서비스 신청
닫기음성서비스 신청 확인
닫기이용약관
닫기학술연구정보서비스 이용약관 (2017년 1월 1일 ~ 현재 적용)
학술연구정보서비스(이하 RISS)는 정보주체의 자유와 권리 보호를 위해 「개인정보 보호법」 및 관계 법령이 정한 바를 준수하여, 적법하게 개인정보를 처리하고 안전하게 관리하고 있습니다. 이에 「개인정보 보호법」 제30조에 따라 정보주체에게 개인정보 처리에 관한 절차 및 기준을 안내하고, 이와 관련한 고충을 신속하고 원활하게 처리할 수 있도록 하기 위하여 다음과 같이 개인정보 처리방침을 수립·공개합니다.
주요 개인정보 처리 표시(라벨링)
목 차
3년
또는 회원탈퇴시까지5년
(「전자상거래 등에서의 소비자보호에 관한3년
(「전자상거래 등에서의 소비자보호에 관한2년
이상(개인정보보호위원회 : 개인정보의 안전성 확보조치 기준)개인정보파일의 명칭 | 운영근거 / 처리목적 | 개인정보파일에 기록되는 개인정보의 항목 | 보유기간 | |
---|---|---|---|---|
학술연구정보서비스 이용자 가입정보 파일 | 한국교육학술정보원법 | 필수 | ID, 비밀번호, 성명, 생년월일, 신분(직업구분), 이메일, 소속분야, 웹진메일 수신동의 여부 | 3년 또는 탈퇴시 |
선택 | 소속기관명, 소속도서관명, 학과/부서명, 학번/직원번호, 휴대전화, 주소 |
구분 | 담당자 | 연락처 |
---|---|---|
KERIS 개인정보 보호책임자 | 정보보호본부 김태우 | - 이메일 : lsy@keris.or.kr - 전화번호 : 053-714-0439 - 팩스번호 : 053-714-0195 |
KERIS 개인정보 보호담당자 | 개인정보보호부 이상엽 | |
RISS 개인정보 보호책임자 | 대학학술본부 장금연 | - 이메일 : giltizen@keris.or.kr - 전화번호 : 053-714-0149 - 팩스번호 : 053-714-0194 |
RISS 개인정보 보호담당자 | 학술진흥부 길원진 |
자동로그아웃 안내
닫기인증오류 안내
닫기귀하께서는 휴면계정 전환 후 1년동안 회원정보 수집 및 이용에 대한
재동의를 하지 않으신 관계로 개인정보가 삭제되었습니다.
(참조 : RISS 이용약관 및 개인정보처리방침)
신규회원으로 가입하여 이용 부탁 드리며, 추가 문의는 고객센터로 연락 바랍니다.
- 기존 아이디 재사용 불가
휴면계정 안내
RISS는 [표준개인정보 보호지침]에 따라 2년을 주기로 개인정보 수집·이용에 관하여 (재)동의를 받고 있으며, (재)동의를 하지 않을 경우, 휴면계정으로 전환됩니다.
(※ 휴면계정은 원문이용 및 복사/대출 서비스를 이용할 수 없습니다.)
휴면계정으로 전환된 후 1년간 회원정보 수집·이용에 대한 재동의를 하지 않을 경우, RISS에서 자동탈퇴 및 개인정보가 삭제처리 됩니다.
고객센터 1599-3122
ARS번호+1번(회원가입 및 정보수정)