Compatibility of new universal simplified adhesives with dual-cured composite and effect of hydrophobic resin coat
저자
발행사항
Seoul : Graduate School, Yonsei University, 2014
학위논문사항
학위논문(석사) -- Graduate School, Yonsei University : Dept. of Dental Science 2014.8
발행연도
2014
작성언어
영어
주제어
발행국(도시)
서울
기타서명
새로운 universal 상아질 접착제의 이원 중합형 복합 레진에 대한 적합성 및 hydrophobic resin coat의 영향
형태사항
vii, 40장 : 삽화 ; 26 cm
일반주기명
지도교수: Byoung-Duck Roh
소장기관
1. Objective
The purpose of this study was to evaluate the influence of two different universal adhesive on microshear bond strength of dual-cured composite to dentin. Also we evaluated the effect of application of a hydrophobic resin coat on the bond strength within the hybrid layer of a one-step self-etch adhesive system.
2. Materials and methods
The flat dentin surfaces were prepared from freshly extracted, caries-free, human third molars. Four recent adhesive systems including two universal adhesive (Single Bond Universal, All-Bond Universal), one-step self-etch system (Tetric N-Bond Self-Etch), etch-and-rinse system (XP bond) and hydrophobic adhesive resin for coating (Heliobond) were evaluated with dual-cured type composite. As a control group, light-cured type flowable composite, with similar flexural strength as dual-cured composite was selected.
Microshear bond test was carried out using a universal testing machine and all debonded specimens with dual-cured composite were observed under X40 stereoscope to determine the mode of failure. Furthermore, specimens in each group with different adhesives were observed under scanning electron microscope for detailed evaluation of surface morphology.
3. Result
Single Bond Universal exhibited the highest bond strength (28.5 ± 6.2 MPa). On the other hand, All-Bond Universal showed low microshear bond strength (14.1 ± 5.1 MPa) and statistically no difference with Tetric N-Bond Self-Etch (8.8 ± 6.7 MPa). Also, with an additional hydrophobic resin coat, Single Bond Universal exhibited significantly higher bond strength than All-Bond Universal. When used with an additional hydrophobic resin coat, the bond strength of all adhesives increased significantly except for Single Bond Universal.
The failure mode of Single Bond Universal was predominantly mixed failure. In case of other adhesives, high percentages of adhesive failure appeared. When a hydrophobic resin coat was applied, Single Bond Universal and All-Bond Universal did not show much difference, whereas Tetric N-bond Self-etch and XP bond showed an increased percentage of mixed failure.
4. Conclusion
(1) With respect to the influence of universal adhesives, Single Bond Universal showed the highest microshear bond strength but not incompatibility with dual-cured composite. However All-Bond Universal showed relatively low microshear bond strength and statistically no difference with Tetric N-Bond Self-Etch as existing one-step self-etch system.
(2) Hydrophobic resin coat may be considerable alternation for solving the problem of incompatibility between single step adhesive system and dual-cured composite, and can improve microshear bond strength of these materials.
분석정보
서지정보 내보내기(Export)
닫기소장기관 정보
닫기권호소장정보
닫기오류접수
닫기오류 접수 확인
닫기음성서비스 신청
닫기음성서비스 신청 확인
닫기이용약관
닫기학술연구정보서비스 이용약관 (2017년 1월 1일 ~ 현재 적용)
학술연구정보서비스(이하 RISS)는 정보주체의 자유와 권리 보호를 위해 「개인정보 보호법」 및 관계 법령이 정한 바를 준수하여, 적법하게 개인정보를 처리하고 안전하게 관리하고 있습니다. 이에 「개인정보 보호법」 제30조에 따라 정보주체에게 개인정보 처리에 관한 절차 및 기준을 안내하고, 이와 관련한 고충을 신속하고 원활하게 처리할 수 있도록 하기 위하여 다음과 같이 개인정보 처리방침을 수립·공개합니다.
주요 개인정보 처리 표시(라벨링)
목 차
3년
또는 회원탈퇴시까지5년
(「전자상거래 등에서의 소비자보호에 관한3년
(「전자상거래 등에서의 소비자보호에 관한2년
이상(개인정보보호위원회 : 개인정보의 안전성 확보조치 기준)개인정보파일의 명칭 | 운영근거 / 처리목적 | 개인정보파일에 기록되는 개인정보의 항목 | 보유기간 | |
---|---|---|---|---|
학술연구정보서비스 이용자 가입정보 파일 | 한국교육학술정보원법 | 필수 | ID, 비밀번호, 성명, 생년월일, 신분(직업구분), 이메일, 소속분야, 웹진메일 수신동의 여부 | 3년 또는 탈퇴시 |
선택 | 소속기관명, 소속도서관명, 학과/부서명, 학번/직원번호, 휴대전화, 주소 |
구분 | 담당자 | 연락처 |
---|---|---|
KERIS 개인정보 보호책임자 | 정보보호본부 김태우 | - 이메일 : lsy@keris.or.kr - 전화번호 : 053-714-0439 - 팩스번호 : 053-714-0195 |
KERIS 개인정보 보호담당자 | 개인정보보호부 이상엽 | |
RISS 개인정보 보호책임자 | 대학학술본부 장금연 | - 이메일 : giltizen@keris.or.kr - 전화번호 : 053-714-0149 - 팩스번호 : 053-714-0194 |
RISS 개인정보 보호담당자 | 학술진흥부 길원진 |
자동로그아웃 안내
닫기인증오류 안내
닫기귀하께서는 휴면계정 전환 후 1년동안 회원정보 수집 및 이용에 대한
재동의를 하지 않으신 관계로 개인정보가 삭제되었습니다.
(참조 : RISS 이용약관 및 개인정보처리방침)
신규회원으로 가입하여 이용 부탁 드리며, 추가 문의는 고객센터로 연락 바랍니다.
- 기존 아이디 재사용 불가
휴면계정 안내
RISS는 [표준개인정보 보호지침]에 따라 2년을 주기로 개인정보 수집·이용에 관하여 (재)동의를 받고 있으며, (재)동의를 하지 않을 경우, 휴면계정으로 전환됩니다.
(※ 휴면계정은 원문이용 및 복사/대출 서비스를 이용할 수 없습니다.)
휴면계정으로 전환된 후 1년간 회원정보 수집·이용에 대한 재동의를 하지 않을 경우, RISS에서 자동탈퇴 및 개인정보가 삭제처리 됩니다.
고객센터 1599-3122
ARS번호+1번(회원가입 및 정보수정)