고도정수처리 공정에서의 천연유기물질 특성변화 및 소독부산물 전구물질의 제거특성 평가 = Changes in characteristics of natural organic matter and DBPs precursor removal by advanced water treatment processes
저자
노재순 (부산광역시 상수도사업본부 수질연구소) ; 손희종 (부산광역시 상수도사업본부 수질연구소) ; 박은주 (부산광역시 상수도사업본부 수질연구소) ; 황영도 (부산광역시 상수도사업본부 수질연구소) ; 최동훈 (부산광역시 상수도사업본부 수질연구소) ; 배석문 (부산광역시 상수도사업본부 수질연구소) ; 신판세 (부산광역시 상수도사업본부 수질연구소)
발행기관
慶星大學校 環境問題硏究所(Environmental Science and Technology Research Center Kyungsung University)
학술지명
環境硏報(Journal of Environmental Science and Technology Research Center)
권호사항
발행연도
2002
작성언어
Korean
주제어
KDC
539
자료형태
학술저널
수록면
115-129(15쪽)
제공처
In this research the movement and apparent molecular weight distribution of hydrophilic/hydrophobic organic matters in advanced water treatment process were investigated using the raw water of Maeri area, located in downstream of Nakdong river, and the variation of the disinfection by-product formation potential was also investigated. In the raw water used in experiments, the content of BDOC (biodegradable dissolved organic carbon) in dissolved organic carbon (DOC) was about 39%, and this value is far above a normal, Pre-ozone treatment showed an increase of 40% in the BDOC content, and this means that biodegradability was remarkably increased by ozone treatment BDOC concentration in BAC treated water was 0.09 mg/L, which means 84% of BDOC removal rate compared with that in post-ozone treated water.
The variation of chlorine disinfection by-product formation potential in each process unit of water treatment process was analyzed. TOXFP concentration in raw water was 449 ㎍/L, and the contents of THMFP and HAAFP among TOXFP were 24% and 23%, respectively. The removabilities of these materials BAC process had an order of TOXFP > HAAFP > THMFP. BAC process was less effective for THMFP than others.
The distribution of hydrophilic organic matters were evaluated in each treatment process. Hydrophilic and hydrophobic matters in the raw water had a ratio of 50 : 50, and the ozone treatment decreased the content of hydrophobic matters. The BAC treatment made the ratio 85:15. These mean that the removal of hydrophilic matters is more difficult than that of hydrophobic materials in water treatment process. In addition the portions of humic and fulvic acid in hydrophobic matters were analyzed. Fulvic acid a large portion among hydrophobic matters in the raw water, and the portion was 78%. Ozone treatment was more effective on the removal of fulvic acid than humic acid. After BAC treatment, the concentration of residual fulvic acid was high than humic acid.
Chlorine disinfection by-product formation for hydrophilic and hydrophobic mattrts was compared in each process unit. in the raw water TOXFP and THMFP formation for hydrophobic matter was higher, and HAAFP was highly formated for hydrophobic matter. After post-ozone or BAC treatment, chlorine disinfection by-product formation has high potential for hydrophobic matters. Comparing humic and fulvic acids, chlorine disinfection by-product formation potential was higher for humic acid than for fulvic acid in all processes. In the comparison of the reactivity with chlorine disinfection by-product per unit DOC, THMFP and DOXFP showed higher reactivity with hydrophobic matter than with hydrophilic matter in all processes, and HAAFP was highly reacitive with hydrophilic matter.
Apparent molecular weight distributions of organic matters were investigated in each process step.The content of low molecular weight organic matters less than 1000 Da in DOC was high in all processes except raw water, but molecular weight organic matters more than 1000 da was higher than molecular weight organic matters less than 1000 Da in the formation potential of chlorine disinfection by-product.
서지정보 내보내기(Export)
닫기소장기관 정보
닫기권호소장정보
닫기오류접수
닫기오류 접수 확인
닫기음성서비스 신청
닫기음성서비스 신청 확인
닫기이용약관
닫기학술연구정보서비스 이용약관 (2017년 1월 1일 ~ 현재 적용)
학술연구정보서비스(이하 RISS)는 정보주체의 자유와 권리 보호를 위해 「개인정보 보호법」 및 관계 법령이 정한 바를 준수하여, 적법하게 개인정보를 처리하고 안전하게 관리하고 있습니다. 이에 「개인정보 보호법」 제30조에 따라 정보주체에게 개인정보 처리에 관한 절차 및 기준을 안내하고, 이와 관련한 고충을 신속하고 원활하게 처리할 수 있도록 하기 위하여 다음과 같이 개인정보 처리방침을 수립·공개합니다.
주요 개인정보 처리 표시(라벨링)
목 차
3년
또는 회원탈퇴시까지5년
(「전자상거래 등에서의 소비자보호에 관한3년
(「전자상거래 등에서의 소비자보호에 관한2년
이상(개인정보보호위원회 : 개인정보의 안전성 확보조치 기준)개인정보파일의 명칭 | 운영근거 / 처리목적 | 개인정보파일에 기록되는 개인정보의 항목 | 보유기간 | |
---|---|---|---|---|
학술연구정보서비스 이용자 가입정보 파일 | 한국교육학술정보원법 | 필수 | ID, 비밀번호, 성명, 생년월일, 신분(직업구분), 이메일, 소속분야, 웹진메일 수신동의 여부 | 3년 또는 탈퇴시 |
선택 | 소속기관명, 소속도서관명, 학과/부서명, 학번/직원번호, 휴대전화, 주소 |
구분 | 담당자 | 연락처 |
---|---|---|
KERIS 개인정보 보호책임자 | 정보보호본부 김태우 | - 이메일 : lsy@keris.or.kr - 전화번호 : 053-714-0439 - 팩스번호 : 053-714-0195 |
KERIS 개인정보 보호담당자 | 개인정보보호부 이상엽 | |
RISS 개인정보 보호책임자 | 대학학술본부 장금연 | - 이메일 : giltizen@keris.or.kr - 전화번호 : 053-714-0149 - 팩스번호 : 053-714-0194 |
RISS 개인정보 보호담당자 | 학술진흥부 길원진 |
자동로그아웃 안내
닫기인증오류 안내
닫기귀하께서는 휴면계정 전환 후 1년동안 회원정보 수집 및 이용에 대한
재동의를 하지 않으신 관계로 개인정보가 삭제되었습니다.
(참조 : RISS 이용약관 및 개인정보처리방침)
신규회원으로 가입하여 이용 부탁 드리며, 추가 문의는 고객센터로 연락 바랍니다.
- 기존 아이디 재사용 불가
휴면계정 안내
RISS는 [표준개인정보 보호지침]에 따라 2년을 주기로 개인정보 수집·이용에 관하여 (재)동의를 받고 있으며, (재)동의를 하지 않을 경우, 휴면계정으로 전환됩니다.
(※ 휴면계정은 원문이용 및 복사/대출 서비스를 이용할 수 없습니다.)
휴면계정으로 전환된 후 1년간 회원정보 수집·이용에 대한 재동의를 하지 않을 경우, RISS에서 자동탈퇴 및 개인정보가 삭제처리 됩니다.
고객센터 1599-3122
ARS번호+1번(회원가입 및 정보수정)