다중표적 뼈 전이암의 하이브리드 세기변조(modified hybrid-VMAT) 방사선치료계획 유용성 평가 = Evaluation of the Modified Hybrid-VMAT for multiple bone metastatic cancer
저자
정일훈 ; 조윤진 ; 장원석 ; 김세준 ; 하진숙 ; 전미진 ; 정인호 ; 김종대 ; 신동봉 ; 이익재 ; Jung, Il Hun ; Cho, Yoon Jin ; Chang, Won Suk ; Kim, Sei Joon ; Ha, Jin Sook ; Jeon, Mi Jin ; Jung, In Ho ; Kim, Jong Dea ; Shin, Dong Bong ; Lee, Ik Jae
발행기관
학술지명
대한방사선치료학회지(The journal of the korean society for radiotherapeutic technology )
권호사항
발행연도
2018
작성언어
Korean
주제어
자료형태
학술저널
수록면
161-167(7쪽)
제공처
목 적 : 동일 선상축(co-axial image)의 다발성 뼈 전이암에 대한 하이브리드 세기변조(modified hybrid-VMAT) 계획의 유용성을 평가하고자 한다. 대상 및 방법 : 동일 선상축의 다발성 뼈 전이암환자 총 5명을 대상으로 치료계획시스템(Ray station, 5.0.2.35, Sweden)을 이용하여 치료계획을 수립하였다. 치료계획용적(planning target volume, PTV) 처방 선량은 30 Gy로 설정하여 총 3가지 치료계획: 용적변조회전치료계획(volumetric modulated arc therapy, VMAT); 배경방사선(background)을 고려하지 않은 하이브리드 용적변조회전치료계획(hybrid VMAT, VMAT(h)); 배경방사선을 고려한 하이브리드 용적변조회전치료계획(modified hybrid VMAT, VMAT(mh))을 비교하였다. 선량용적히스토그램(dose volume histogram, DVH)을 이용하여 PTV의 maximum dose($D_{max}$), mean dose($D_{mean}$), 처방선량지수(conformity index, CI), 선량균질지수(homogeneity Index, HI) 및 손상위험장기(organ at risk, OAR)의 선량을 분석하였다. 또한 monitor unit(MU)와 치료시간(beam on time)을 분석하였다. 결 과 : VMAT, VMAT(h)과 VMAT(mh)의 PTV $D_{max}$는 3188.33 cGy, 3526 cGy, 3285.67 cGy이고, $D_{mean}$은 3081 cGy, 3252 cGy, 3094 cGy이고, CI는 $1.35{\pm}0.19$, $1.43{\pm}0.12$, $1.30{\pm}0.06$이고, HI는 $1.06{\pm}0.01$, $1.14{\pm}0.06$, $1.09{\pm}0.02$로 평가되었다. VMAT(h)과 VMAT(mh)의 OAR은 3 % 증가와 18 % 감소하는 것으로 평가되었다. 추가적으로 평균 MU는 904.90, 911.73, 1202.13 그리고 평균 Beam on time은 $128.67{\pm}10.97$초, $167.33{\pm}7.57$초, $190.33{\pm}4.51$초 소요되었다. 결 론 : 다중표적 치료 시에는 modified Hybrid-VMAT를 적용하면 선량의 겹침이 보정되어 과선량(over dose) 조사되는 것을 방지하는 다중표적을 치료할 수 있다. 그리고 PTV의 선량포함을 만족하면서 주위의 정상장기를 더 효과적으로 보호할 수 있는 치료계획이 가능하다. 또한 modified Hybrid-VMAT의 임상적 효능을 확인하기 위해 많은 수의 환자를 대상으로 한 장기 추적 관찰이 필요하다.
더보기Purpose : This study evaluates the usefulness of the Modified Hybrid-VMAT scheme with consideration of background radiation when establishing a treatment plan for multiple bone metastatic cancer including multiple tumors on the same axis. Materials and Methods : The subjects of this study consisted of five patients with multiple bone metastatic cancer on the same axis. The planning target volume(PTV) prescription dose was 30 Gy, and the treatment plan was established using Ray Station(Ray station, 5.0.2.35, Sweden). In the treatment plan for each patient, two or more tumors were set as one isocenter. A volumetric modulated arc therapy(VMAT) plan, a hybrid VMAT(h) plan with no consideration of background radiation, and a modified hybrid VMAT(mh) with consideration of background radiation were established. Then, using each dose volume histogram(DVH), the PTV maximum dose($D_{max}$), mean dose($D_{mean}$), conformity index(CI), and homogeneity index(HI) were compared among the plans. In addition, the organ at risk(OAR) of each treatment site was evaluated, and the total MU(Monitor Unit) and treatment time were also analyzed. Results : The PTV $D_{max}$ values of VMAT, VMAT(h) and VMAT(mh) were 3188.33 cGy, 3526 cGy, and 3285.67 cGy, the $D_{mean}$ values were 3081 cGy, 3252 cGy, and 3094 cGy; the CI values were $1.35{\pm}0.19$, $1.43{\pm}0.12$, and $1.30{\pm}0.06$; the HI values were $1.06{\pm}0.01$, $1.14{\pm}0.06$, and $1.09{\pm}0.02$; and the VMAT(h) OAR value was increased 3 %, and VMAT(mh) OAR value was decreased 18 %, respectively. Furthermore, the mean MU values were 904.90, 911.73, and 1202.13, and the mean beam on times were $128.67{\pm}10.97$, $167.33{\pm}7.57$, and $190.33{\pm}4.51$ respectively. Conclusions : Applying Modified Hybrid-VMAT when treating multiple targets can prevent overdose by correcting the overlapping of doses. Furthermore, it is possible to establish a treatment plan that can protect surrounding normal organs more effectively while satisfying the inclusion of PTV dose. Long-term follow-up of many patients is necessary to confirm the clinical efficacy of Modified Hybrid-VMAT.
더보기분석정보
서지정보 내보내기(Export)
닫기소장기관 정보
닫기권호소장정보
닫기오류접수
닫기오류 접수 확인
닫기음성서비스 신청
닫기음성서비스 신청 확인
닫기이용약관
닫기학술연구정보서비스 이용약관 (2017년 1월 1일 ~ 현재 적용)
학술연구정보서비스(이하 RISS)는 정보주체의 자유와 권리 보호를 위해 「개인정보 보호법」 및 관계 법령이 정한 바를 준수하여, 적법하게 개인정보를 처리하고 안전하게 관리하고 있습니다. 이에 「개인정보 보호법」 제30조에 따라 정보주체에게 개인정보 처리에 관한 절차 및 기준을 안내하고, 이와 관련한 고충을 신속하고 원활하게 처리할 수 있도록 하기 위하여 다음과 같이 개인정보 처리방침을 수립·공개합니다.
주요 개인정보 처리 표시(라벨링)
목 차
3년
또는 회원탈퇴시까지5년
(「전자상거래 등에서의 소비자보호에 관한3년
(「전자상거래 등에서의 소비자보호에 관한2년
이상(개인정보보호위원회 : 개인정보의 안전성 확보조치 기준)개인정보파일의 명칭 | 운영근거 / 처리목적 | 개인정보파일에 기록되는 개인정보의 항목 | 보유기간 | |
---|---|---|---|---|
학술연구정보서비스 이용자 가입정보 파일 | 한국교육학술정보원법 | 필수 | ID, 비밀번호, 성명, 생년월일, 신분(직업구분), 이메일, 소속분야, 웹진메일 수신동의 여부 | 3년 또는 탈퇴시 |
선택 | 소속기관명, 소속도서관명, 학과/부서명, 학번/직원번호, 휴대전화, 주소 |
구분 | 담당자 | 연락처 |
---|---|---|
KERIS 개인정보 보호책임자 | 정보보호본부 김태우 | - 이메일 : lsy@keris.or.kr - 전화번호 : 053-714-0439 - 팩스번호 : 053-714-0195 |
KERIS 개인정보 보호담당자 | 개인정보보호부 이상엽 | |
RISS 개인정보 보호책임자 | 대학학술본부 장금연 | - 이메일 : giltizen@keris.or.kr - 전화번호 : 053-714-0149 - 팩스번호 : 053-714-0194 |
RISS 개인정보 보호담당자 | 학술진흥부 길원진 |
자동로그아웃 안내
닫기인증오류 안내
닫기귀하께서는 휴면계정 전환 후 1년동안 회원정보 수집 및 이용에 대한
재동의를 하지 않으신 관계로 개인정보가 삭제되었습니다.
(참조 : RISS 이용약관 및 개인정보처리방침)
신규회원으로 가입하여 이용 부탁 드리며, 추가 문의는 고객센터로 연락 바랍니다.
- 기존 아이디 재사용 불가
휴면계정 안내
RISS는 [표준개인정보 보호지침]에 따라 2년을 주기로 개인정보 수집·이용에 관하여 (재)동의를 받고 있으며, (재)동의를 하지 않을 경우, 휴면계정으로 전환됩니다.
(※ 휴면계정은 원문이용 및 복사/대출 서비스를 이용할 수 없습니다.)
휴면계정으로 전환된 후 1년간 회원정보 수집·이용에 대한 재동의를 하지 않을 경우, RISS에서 자동탈퇴 및 개인정보가 삭제처리 됩니다.
고객센터 1599-3122
ARS번호+1번(회원가입 및 정보수정)