흉부 CT검사 시 검사부위를 벗어난 Topogram 부위에 Automatic Exposure Control 적용이 선량 및 화질에 미치는 영향 = Automatic Exposure Control Systems with Inappropriate Topogram: A Phantom study in Chest CT on Radiation dose and Image quality between different manufactures
저자
박관중(Guan Jung Park) ; 김영옥(Young Ok Kim) ; 여상근(Sang Geun Yeo) ; 대창민(Chang Min Dae) ; 민관홍(Kwan Hong Min)
발행기관
학술지명
대한CT영상기술학회지(Journal of Korean society of cumputed tomographic technology)
권호사항
발행연도
2011
작성언어
-주제어
KDC
512.151
등재정보
KCI등재후보
자료형태
학술저널
발행기관 URL
수록면
227-238(12쪽)
제공처
목적 임상에서 많이 시행하고 있는 흉부 computed tomography(이하 CT) 검사 시, 세 개의 각기 다른 CT장비 제조사의 automatic exposure control(이하 AEC) system을 인체 등가phantom에 적용하여, 검사부위를 벗어난 topogram을 검사하였다. 검사부위를 벗어난 topogram에서 AEC작동유무 및 CT dose index volume(이하 CTDI) 변화를 측정하고, 영상의 노이즈값의 비교를 통하여 선량 및 화질 변화를 알아보고자 하였다. 대상 및 방법 사용된 각 장비 회사별 CT 장비는 Brilliance 64 MDCT(Philips healthcare, 이하 P사), LightSpeed VCT XT 64 MIDCT(General Electric Medical System, 이하 G사), Somatom Definition Dual CT(Siemens Healthcare, 이하 S사)를 사용하였다. Rando phantom을 대상으로 하여 본원에서 흉부 검사 범위로 정하고 있는 성대에서 부신이 충분히 포함된 topogram을 정상군으로 정하고, 정상군과 비교하여 폐첨부에서 머리 방향쪽으로 2cm 검사부위를 벗어난 군을 A군, 4cm는 B군, 6cm는 C군, 8cm를 D군으로 대조군을 정하였다. 선량 평가를 위해 각 장비 제조회사에서 제공하는 CTDI값과 ionization chamber를 이용하여 CTDI값을 실측한 후, 정상군의 CTDI값을 기준으로 대조군의 CTDI 증감률을 산출하였다. 화질 평가는 AAPM phantom을 이용하여 정상군 및 대조군 실험 영상의 6시 방향 1/4지점에서 4×4cm의 크기의 region of interest(이하 ROI)를 설정하여 모든 slice의 평균오차의 값을 노이즈값으로 계산하여 평가하였다. 결과 정상적인 topogram과 검사부위를 벗어난 topogram의 AEC적용 결과는 P사의 경우는 ACS만 적용 시 노이즈값은 정상군은 12.9, A군은 약 12.7(p=0.0273, B군은 약 12.6(p=0.0195), C군은 약 12.2(p=0.002), D군은 약 12.l(p=0.002)로 측정되었으며, 대조군의 CTDI 증감률은 정상군과 비교하여 각 군에서 약 8.9%, 11.1%, 14.4%, 15.6% 증가하였다. ACS combined Z-DOM 적용 시에는 정상군 비교하여 CTDI 증감률은 각 군에서 약 3.0%, 4.0%, 4.0%, 5.0% 증가하지만, 노이즈값은 각 군에서 약 13.3, 약 13.2(p=0.0216), 13.1(p=0.0078), 12.9(p=0.0195), 12.9(p=0.0039)로 측정되었다. ACS combined D-DOM 적용 시에는 CTDI 증감률은 정상군 비교하여 각 군에서 약 0.9%, 1.8%, 1.8%, 2.7% 증가하였고, 노이즈값은 정상군은 약 12.7, 대조군은 약 12.6(p=0.0301), 12.5(p=0.0392), 12.5(p=0.0391), 12(p=0.002)로 통계학적으로 유의한 차이가 없었다. S사의 경우에는 노이즈값은 각 군에서 약 8.0, 7.9(p=0.0376), 7.6(p=0.0277), 7.5(p=0.002), 7.3(p=0.002)로 통계학적으로 유의한 차이가 없었다. CTDI 증감률은 정상군 비교하여 각 군에서 약 1.2%, 3.4%, 2.3%, 6.9% 증가하였다. G사의 경우는 Auto mA 적용 시, 정상군의 노이즈값은 약 45.0, A군은 약 44.1(p<0.0001), B군은 약 44.1(p<0.0001), C군은 약 44.1(p<0.0001), D군은 약 44.1(p<0.0001)으로 대조군에서는 모두 동일한 결과로 측정되었다. 정상군과 비교하여 대조군 모두 통계학적으로 유의한 차이가 없이, CTDI 증감률은 정상군과 비교하여 모든 대조군에서 동일하게 약 8.1% 증가를 보였다. 결론 검사부위를 벗어난 topogram을 얻은 후, topogram에 포함되지 않은 영역에 AEC를 적용하게 되면, 각 장비 회사마다 다소 차이는 있지만 영상의 질적 차이 없이 방사선 피폭선량이 최소 약 0.9%에서 최대 15.6% 증가하였다. 따라서 AEC를 적용 시 정확한 환자의 위치잡이가 선행되어야 topogram을 통해 정확한 정보를 얻을 수 있다. 그 정보를 바탕으로 AEC가 올바르게 동작하여 선량의 최적화를 달성할 수 있을 것으로 사료된다.
더보기I. Purpose The purpose of this study is to investigate the change of radiation dose and image quality in outside topogram of scan range applying automatic exposure control (AEC) through phantom study in chest CT. II. Meterial and Methods A Rando anthropomorphic chest phantom and AAPM phantom was scanned on a 64 multi detector CT using the AEC systems from three different manufacturers: General Electric Healthcare, Philips Medical Systems and Siemens Medical Solutions. A general scanning protocol was created for each examination where as many as possible of the scanning parameters were set equal. Divided into 5 groups according to include and not be scan range of topogram. Topogram, normally including scan range, is defined normal group. If not was control group, the group which was 2 an outside topogram of scan range toward head from lung apex was designated as A group, B group in 4 cm off, C group in 6 an off, and D group in 8 an off. CTDI was measured using ionization chamber and provided by CT modality. CTDI fluctuation ratios of control groups were calculated based on the values of CTDI in normal group. For the evaluation of image quality, mean error value was assessed by the image noise from AAPM phantom. III. Result As a result of application of AEC to normal and control groups, in case of P, when applying only ACS, noise of normal group was 12.9, 12.7(p=0.0273) in A group, 12.6(p=0.0195) in B group, 12.2(p=0.002) in C group, 12.1(p=0.002) in D group. CTDI fluctuation ratios of control group was increased by 8.9%i, 11.1%, 14.4%, 15.6% respectively in each group compared to normal group. When applying ACS combined Z-OOM, the CTDI fluctuation ratios of control groups was increased by 3.0%, 4.0%, 4.0%, 5.0% respectively, compared to normal group. However, noise was appeared to be 13.3, 13.2(p=0.0216), 13.1(p=0.0078), 12.9(p=0.0195), 12.9(p=0.0039). When applying ACS combined D-DOM, the CTDI fluctuation ratios was increased by 0.9%, 1.8%, 1.8%, 2.7% while noise value in normal group was 12.7, 12.6(p=0.0301), 12.5(p=0.0392, 12.5(p=0.0391), 12(p=0.002). No statistical significant difference was found. In case of S, noise appeared to be 8.0, 7.9(p=0.0376), 7.6(p=0.0277), 7.5(p=0.002), 7.3(p=0.002) respectively in each group leading to no statistical significant difference. CTDI fluctuation ratios, comparing to normal group, was increased by 1.2%, 3.4%, 2.3%, 6.9%. In case of G, when applying AutomA, the noise of normal group was measured to be 4.0, and 44.1(p<0.0001) in A~D control groups, Compared to normal group, there was no statistical significant difference in control groups, and also the fluctuation ratio (%) of CTDI showed the same ratio of 8.1% in all control groups. IV. Conclusions Radiation dose by different mmufacturer was increased by at minimum 0.9% up to at maximum 15.6%. And it was little difference of image quality found at all. Consequently, projection of topogram, normally included scan range, is very important applying AEC in CT examination.
더보기분석정보
서지정보 내보내기(Export)
닫기소장기관 정보
닫기권호소장정보
닫기오류접수
닫기오류 접수 확인
닫기음성서비스 신청
닫기음성서비스 신청 확인
닫기이용약관
닫기학술연구정보서비스 이용약관 (2017년 1월 1일 ~ 현재 적용)
학술연구정보서비스(이하 RISS)는 정보주체의 자유와 권리 보호를 위해 「개인정보 보호법」 및 관계 법령이 정한 바를 준수하여, 적법하게 개인정보를 처리하고 안전하게 관리하고 있습니다. 이에 「개인정보 보호법」 제30조에 따라 정보주체에게 개인정보 처리에 관한 절차 및 기준을 안내하고, 이와 관련한 고충을 신속하고 원활하게 처리할 수 있도록 하기 위하여 다음과 같이 개인정보 처리방침을 수립·공개합니다.
주요 개인정보 처리 표시(라벨링)
목 차
3년
또는 회원탈퇴시까지5년
(「전자상거래 등에서의 소비자보호에 관한3년
(「전자상거래 등에서의 소비자보호에 관한2년
이상(개인정보보호위원회 : 개인정보의 안전성 확보조치 기준)개인정보파일의 명칭 | 운영근거 / 처리목적 | 개인정보파일에 기록되는 개인정보의 항목 | 보유기간 | |
---|---|---|---|---|
학술연구정보서비스 이용자 가입정보 파일 | 한국교육학술정보원법 | 필수 | ID, 비밀번호, 성명, 생년월일, 신분(직업구분), 이메일, 소속분야, 웹진메일 수신동의 여부 | 3년 또는 탈퇴시 |
선택 | 소속기관명, 소속도서관명, 학과/부서명, 학번/직원번호, 휴대전화, 주소 |
구분 | 담당자 | 연락처 |
---|---|---|
KERIS 개인정보 보호책임자 | 정보보호본부 김태우 | - 이메일 : lsy@keris.or.kr - 전화번호 : 053-714-0439 - 팩스번호 : 053-714-0195 |
KERIS 개인정보 보호담당자 | 개인정보보호부 이상엽 | |
RISS 개인정보 보호책임자 | 대학학술본부 장금연 | - 이메일 : giltizen@keris.or.kr - 전화번호 : 053-714-0149 - 팩스번호 : 053-714-0194 |
RISS 개인정보 보호담당자 | 학술진흥부 길원진 |
자동로그아웃 안내
닫기인증오류 안내
닫기귀하께서는 휴면계정 전환 후 1년동안 회원정보 수집 및 이용에 대한
재동의를 하지 않으신 관계로 개인정보가 삭제되었습니다.
(참조 : RISS 이용약관 및 개인정보처리방침)
신규회원으로 가입하여 이용 부탁 드리며, 추가 문의는 고객센터로 연락 바랍니다.
- 기존 아이디 재사용 불가
휴면계정 안내
RISS는 [표준개인정보 보호지침]에 따라 2년을 주기로 개인정보 수집·이용에 관하여 (재)동의를 받고 있으며, (재)동의를 하지 않을 경우, 휴면계정으로 전환됩니다.
(※ 휴면계정은 원문이용 및 복사/대출 서비스를 이용할 수 없습니다.)
휴면계정으로 전환된 후 1년간 회원정보 수집·이용에 대한 재동의를 하지 않을 경우, RISS에서 자동탈퇴 및 개인정보가 삭제처리 됩니다.
고객센터 1599-3122
ARS번호+1번(회원가입 및 정보수정)