SCOPUS
KCI등재
SCIE
이중관을 이용한 체외순환식 탄산가스 제거법에 관한 연구 = An Experimental Study on the Extracorporeal Carbon Dioxide Removal with a Double Lumen Tube
저자
함병문 (부천세종병원) ; 곽일룡 (서울대학교 의과대학 마취과학교실) ; 성시옥 (서울대학교 의과대학 마취과학교실)
발행기관
학술지명
Korean Journal of Anesthesiology(Korean Journal of Anesthesiology)
권호사항
발행연도
1993
작성언어
Korean
KDC
514.000
등재정보
SCOPUS,KCI등재,SCIE
자료형태
학술저널
발행기관 URL
수록면
412-425(14쪽)
제공처
중단사유
※ 발행기관의 정책으로 인하여 개인 판매가 중단된 논문입니다. 구독기관 이용자는 [
Intermittent positive pressure ventilation is used as a respiratory support for acute respiratroy failure. Adult respiratory distress syndrome(ARDS) revealed mortality rate of 70% as yet. Hypoxemia is foremost problem in ARDS. Though various ventilatory support is tried on ARDS, extracorporeal membrane oxygenation(ECMO) is to be recommended when hypoxemia and hypercarbia are refractory to conventional treatments. Neonatal venoarterial (VA) ECMO in USA is recognized as a therapeutic modality for neonatal respiratory failure and extracorporeal carhon dioxide removal(ECCO₂R) in Europe is used for adult respiratory distress syndome. The partial bypass using the membrane oxygenator aims at lung rest while relieving the hard ventilatory setting on the diseased lung. VA ECMO can provide circulatory support as well but the right internal jugular vein and the right common carotid artery are ligated for the cannulation of draiaage and perfusion catheters. Recent follow up study shows that VA ECMO may not be completelyfree from neurologic complications such as embolism in the systemic circulation and ill effects due to the reduction of blood supply to the immature lungs. ECCO₂R adopts low-flow venovenous(VV) bypass. It has been reported to be valuable for treatment of neonatal respiratory failure. VV bypass provides gas exchange but no cardiac support. Venous drainage and perfusion catheters are placed in the right atrium or vena cavae via the femoral or internal jugular veins. Compared to VA bypass, the consequences of embolizations are potentially fewer, no major artery is sacrificed. Highly oxygenated blood flows into pulmonary eirculatiom which may relieve pulmonary artery hypertension. Total respiratory support may be obtained by VV bypass, VV bypass requires approximately 20-50% more flow for total respiratory sopport due to recirculation of oxygenated blood. Recently VV bypass is chosen for neonatal resyiratoty failure in USA. They alliveate the entry criteria for ECMO using the parameter of oxygenation index(OI). V ECCO₂R using to-and-fro system is tried also for neonatal respiratory failure in Europe. A double lumen tube was developed to reduce the number of veins to be cannulated during VV bypass. It is constructed with the outer drainage cannula(14 Fr.) and the inner perfusion cannula(8 Fr.) whose opening is placed on the left side of outer cannula. If perfusion opening is placed on the right atrium facing the right ventricle, the venous blood can be drained from both superior and inferior vena cavae through several drainage opening. To evaluate the effectiveness of ECCO₂R with a double lumen tube, we developed an experimental model of acute respiratory failure on 8 mongrel dogs. Under general anesthesia with i.v, pentobarbital, a double lumen tube was introduced via the right internal jugular vein and it was connected with the extracorporeal circuit. Without ventilating the oxygenator during VV bypass, respiratory failure was induced by hypoventilation. After obtaining control hemodynamic and blood gas values der hypoventilation, we proceed to apneic oxygenation(AO), extracorporeal CO₂ removal(ECCO₂R) and controlled mechanical ventilation(CMV) in that order. Arterial pH in control was 7.180.09(meanSD), and it was increased to 7.33±0.08 and 7.28±0.08 in ECCO₂R and CMV, respectively. PaCO₂ in control was 69±9mmHg and it was decreased to 41±4mmHg and 47±7mmHg in ECCO R and CMV respectively. PaCO₂ in control was 62±15 mmHg and it was increased in AO, ECCO₂R and CMV. Mixed venous blood gas analysis showed the same result as arterial blood gas analysis. There was no difference between ECCO₂R and CMV. The bypass flow enough to remove CO₂ was 30∼50% of cardiac output. It is concluded that ECCO₂R using a double lumen tube was effective to control the carbon dioxide tension in arterial blood, and a double lumen tube may permit the simplicity of an operation and patient care as well as minimizing the bleeding during extracorporeal respiratory support
서지정보 내보내기(Export)
닫기소장기관 정보
닫기권호소장정보
닫기오류접수
닫기오류 접수 확인
닫기음성서비스 신청
닫기음성서비스 신청 확인
닫기이용약관
닫기학술연구정보서비스 이용약관 (2017년 1월 1일 ~ 현재 적용)
학술연구정보서비스(이하 RISS)는 정보주체의 자유와 권리 보호를 위해 「개인정보 보호법」 및 관계 법령이 정한 바를 준수하여, 적법하게 개인정보를 처리하고 안전하게 관리하고 있습니다. 이에 「개인정보 보호법」 제30조에 따라 정보주체에게 개인정보 처리에 관한 절차 및 기준을 안내하고, 이와 관련한 고충을 신속하고 원활하게 처리할 수 있도록 하기 위하여 다음과 같이 개인정보 처리방침을 수립·공개합니다.
주요 개인정보 처리 표시(라벨링)
목 차
3년
또는 회원탈퇴시까지5년
(「전자상거래 등에서의 소비자보호에 관한3년
(「전자상거래 등에서의 소비자보호에 관한2년
이상(개인정보보호위원회 : 개인정보의 안전성 확보조치 기준)개인정보파일의 명칭 | 운영근거 / 처리목적 | 개인정보파일에 기록되는 개인정보의 항목 | 보유기간 | |
---|---|---|---|---|
학술연구정보서비스 이용자 가입정보 파일 | 한국교육학술정보원법 | 필수 | ID, 비밀번호, 성명, 생년월일, 신분(직업구분), 이메일, 소속분야, 웹진메일 수신동의 여부 | 3년 또는 탈퇴시 |
선택 | 소속기관명, 소속도서관명, 학과/부서명, 학번/직원번호, 휴대전화, 주소 |
구분 | 담당자 | 연락처 |
---|---|---|
KERIS 개인정보 보호책임자 | 정보보호본부 김태우 | - 이메일 : lsy@keris.or.kr - 전화번호 : 053-714-0439 - 팩스번호 : 053-714-0195 |
KERIS 개인정보 보호담당자 | 개인정보보호부 이상엽 | |
RISS 개인정보 보호책임자 | 대학학술본부 장금연 | - 이메일 : giltizen@keris.or.kr - 전화번호 : 053-714-0149 - 팩스번호 : 053-714-0194 |
RISS 개인정보 보호담당자 | 학술진흥부 길원진 |
자동로그아웃 안내
닫기인증오류 안내
닫기귀하께서는 휴면계정 전환 후 1년동안 회원정보 수집 및 이용에 대한
재동의를 하지 않으신 관계로 개인정보가 삭제되었습니다.
(참조 : RISS 이용약관 및 개인정보처리방침)
신규회원으로 가입하여 이용 부탁 드리며, 추가 문의는 고객센터로 연락 바랍니다.
- 기존 아이디 재사용 불가
휴면계정 안내
RISS는 [표준개인정보 보호지침]에 따라 2년을 주기로 개인정보 수집·이용에 관하여 (재)동의를 받고 있으며, (재)동의를 하지 않을 경우, 휴면계정으로 전환됩니다.
(※ 휴면계정은 원문이용 및 복사/대출 서비스를 이용할 수 없습니다.)
휴면계정으로 전환된 후 1년간 회원정보 수집·이용에 대한 재동의를 하지 않을 경우, RISS에서 자동탈퇴 및 개인정보가 삭제처리 됩니다.
고객센터 1599-3122
ARS번호+1번(회원가입 및 정보수정)