Size-Specific Dose Estimates의 유용성 평가 = Usefulness of Size-Specific Dose Estimates : Current issues & Introduction
저자
임진희(Jin Hee Lim) ; 정용환(Yong Hwan Jung) ; 대창민(Chang Min Dae) ; 김성룡(Seong Ryong Kim) ; 민관홍(Kwan Hong Min)
발행기관
학술지명
대한CT영상기술학회지(Journal of Korean society of cumputed tomographic technology)
권호사항
발행연도
2013
작성언어
-주제어
KDC
510
등재정보
KCI등재후보
자료형태
학술저널
발행기관 URL
수록면
187-199(13쪽)
제공처
목적 : 2011년에 발표된 AAPM report 204에서는 volume CT Dose Index(이하 CTDIvol)와 Dose Length Product(이하 DLP)의 선량표현 방법으로는 환자마다 정확한 선량을 제공하는데 한계가 있기 때문에 Size-Specific Dose Estimates(이하 SSDE)라는 새로운 환자의 선량을 표현하는 방법을 제시해 사용을 권고하고 있다. 따라서 본 논문은 SSDE가 환자가 가진 고유 정보와 장비에서 제공되는 CTDIvol, DLP, Effective Dose(이하 ED)와의 상관관계를 알아보고 개인별 선량표현 방법으로써 임상에 적용하여 선량의 표준화 작업에 사용하고자 한다.
대상 및 방법 : Phantom연구는 Norris(이하 N), Wendy(이하 W)와 Whole body phantom(이하 P)의 세 팬텀을 256-slice MDCT(이하 Scanner A)로 촬영하여 Anteroposterior Diameter(이하 AP Di), Lateral Diameter(이하 Lat Di), AP와 Lat의 합(이하 SUM), Effective Diameter(이하 Eff Di)를 각각 SSDE로 변환하여 비교하였다.
임상연구는 2012년 8월에 본원을 내원하여 복부 골반 CT 검사를 시행한 921명(대조군)과 11월 같은 검사를 받은 850명(실험군)을 대상으로 하였으며, 사용한 장비는 Scanner A와, 64-slice MDCT 3대(이하 Scanner B, C, D)로 총 4대의 Scanner를 이용하였다.
대조군의 Eff Di와 SSDE를 측정하여 나이, 키, 몸무게, Body Mass Index, Eff Di, CTDIvol, ED와의 상관관계를 각 장비별로 분석하였고, median SSDE와 실험군의 Reference mAs를 대조군의 median SSDE 최솟값에 맞춰 적용하여 같은 방법으로 측정 후 각 장비별 median SSDE를 비교하였다.
결과 : phantom 측정 결과 N, W, P에서 SSDE가 각각 Diaphragm level에서 17±1, 18±1, 13±1 mGy, Pubic symphysis level에서 17±1, 16±1, 13±1 mGy가 나왔다. 대조군의 median SSDE는 Scanner A~D가 각각 16.0, 13.9, 13.6, 16.3 mGy로 나타났다. 대조군의 SSDE와 나이, 키, 몸무게, BMI, Eff Di, ED, CTDIvol, DLP와의 상관관계를 분석한 결과 독립적으로 나타났다. 실험군의 SSDE를 최솟값인 13.6(±10%)으로 QA하기 위하여 Scanner A와 D의 reference mAs를 215 mAs과 230 mAs로 변경하여 시행한 결과 median SSDE는 각각 13.8, 13.9, 13.4, 13.3 mGy로 나타났다.
결론 : SSDE는 AP Di, Lat Di, SUM, Eff Di 중에 어떤 방법으로 얻어도 오차범위 안으로 나타났고, 독립적인 변수이며 장비 선량의 표준화 작업을 할 때 적정한 선량 수준을 평가하기 위한 지표로 활용할 수 있다. 따라서 환자의 선량을 표현하고자 하는 경우 장비의 특성을 고려하여 표현하는 CTDIvol, DLP와 함께 환자의 특성을 고려한 SSDE도 표시 하는 것이 더욱 바람직하다고 사료된다.
Purpose : AAPM report 204 present a way to express a new dose to the patient, the Size- Specific Dose Estimates(SSDE) is recommended. In this paper, therefore, to suggest SSDE as the individual dose to the patient and the indicator of Radiation Dose Quality Assurance(QA).
Materials and Methods : We compared SSDE from the largest anteroposterior(AP), lateral, sum of those diameters and effective diameter of the phantoms, Norris(N), Wendy(W) and Whole body phantom(P) using 256-slice MDCT. The clinical study was performed by 921 patients in August and 850 patients in November underwent Abdomen & Pelvis CT using scanner A and 3 64-slice MDCT scanners(B, C and D). We analyzed correlation between SSDE and the factors(age, height, weight, body mass index(BMI), effective diameter(Eff Di), CTDIvol, DLP, effective dose(ED) by each equipment and compared SSDE between experimental group and control group which reference mAs was changed to the target mAs.
Results : In the phantom study, SSDE was 17±1, 18±1, 13±1mGy at the diaphragm level and 17±1, 16±1, 13±1 mGy at the Pubic symphysis level. In the clinical study, median SSDE of control group was 16.0, 13.9, 13.6, 16.3 mGy in each. Reference mAs was changed to target mAs, then median SSDE of experimental group was 13.8 13.9 13.4 13.3 mGy.
Conclusions : SSDE is an independent factor and is unrelated with the characteristics and scanner output. We suggest to indicate SSDE as patient’s dose with CTDIvol and DLP.
서지정보 내보내기(Export)
닫기소장기관 정보
닫기권호소장정보
닫기오류접수
닫기오류 접수 확인
닫기음성서비스 신청
닫기음성서비스 신청 확인
닫기이용약관
닫기학술연구정보서비스 이용약관 (2017년 1월 1일 ~ 현재 적용)
학술연구정보서비스(이하 RISS)는 정보주체의 자유와 권리 보호를 위해 「개인정보 보호법」 및 관계 법령이 정한 바를 준수하여, 적법하게 개인정보를 처리하고 안전하게 관리하고 있습니다. 이에 「개인정보 보호법」 제30조에 따라 정보주체에게 개인정보 처리에 관한 절차 및 기준을 안내하고, 이와 관련한 고충을 신속하고 원활하게 처리할 수 있도록 하기 위하여 다음과 같이 개인정보 처리방침을 수립·공개합니다.
주요 개인정보 처리 표시(라벨링)
목 차
3년
또는 회원탈퇴시까지5년
(「전자상거래 등에서의 소비자보호에 관한3년
(「전자상거래 등에서의 소비자보호에 관한2년
이상(개인정보보호위원회 : 개인정보의 안전성 확보조치 기준)개인정보파일의 명칭 | 운영근거 / 처리목적 | 개인정보파일에 기록되는 개인정보의 항목 | 보유기간 | |
---|---|---|---|---|
학술연구정보서비스 이용자 가입정보 파일 | 한국교육학술정보원법 | 필수 | ID, 비밀번호, 성명, 생년월일, 신분(직업구분), 이메일, 소속분야, 웹진메일 수신동의 여부 | 3년 또는 탈퇴시 |
선택 | 소속기관명, 소속도서관명, 학과/부서명, 학번/직원번호, 휴대전화, 주소 |
구분 | 담당자 | 연락처 |
---|---|---|
KERIS 개인정보 보호책임자 | 정보보호본부 김태우 | - 이메일 : lsy@keris.or.kr - 전화번호 : 053-714-0439 - 팩스번호 : 053-714-0195 |
KERIS 개인정보 보호담당자 | 개인정보보호부 이상엽 | |
RISS 개인정보 보호책임자 | 대학학술본부 장금연 | - 이메일 : giltizen@keris.or.kr - 전화번호 : 053-714-0149 - 팩스번호 : 053-714-0194 |
RISS 개인정보 보호담당자 | 학술진흥부 길원진 |
자동로그아웃 안내
닫기인증오류 안내
닫기귀하께서는 휴면계정 전환 후 1년동안 회원정보 수집 및 이용에 대한
재동의를 하지 않으신 관계로 개인정보가 삭제되었습니다.
(참조 : RISS 이용약관 및 개인정보처리방침)
신규회원으로 가입하여 이용 부탁 드리며, 추가 문의는 고객센터로 연락 바랍니다.
- 기존 아이디 재사용 불가
휴면계정 안내
RISS는 [표준개인정보 보호지침]에 따라 2년을 주기로 개인정보 수집·이용에 관하여 (재)동의를 받고 있으며, (재)동의를 하지 않을 경우, 휴면계정으로 전환됩니다.
(※ 휴면계정은 원문이용 및 복사/대출 서비스를 이용할 수 없습니다.)
휴면계정으로 전환된 후 1년간 회원정보 수집·이용에 대한 재동의를 하지 않을 경우, RISS에서 자동탈퇴 및 개인정보가 삭제처리 됩니다.
고객센터 1599-3122
ARS번호+1번(회원가입 및 정보수정)