SCOPUS
SCIE
Whole-Body Voxel-Based Personalized Dosimetry: The Multiple Voxel S-Value Approach for Heterogeneous Media with Nonuniform Activity Distributions
저자
Lee, Min Sun ; Kim, Joong Hyun ; Paeng, Jin Chul ; Kang, Keon Wook ; Jeong, Jae Min ; Lee, Dong Soo ; Lee, Jae Sung
발행기관
학술지명
권호사항
발행연도
2018
작성언어
-주제어
등재정보
SCOPUS,SCIE
자료형태
학술저널
수록면
1133-1139(7쪽)
제공처
<P>Personalized dosimetry with high accuracy is becoming more important because of the growing interest in personalized medicine and targeted radionuclide therapy. Voxel-based dosimetry using dose point kernel or voxel S-value (VSV) convolution is available. However, these approaches do not consider the heterogeneity of the medium. Here, we propose a new method for whole-body voxel-based personalized dosimetry in heterogeneous media with nonuniform activity distributions—a method we refer to as the multiple VSV approach. Instead of using only a single VSV, as found in water, the method uses multiple numbers (<I>N</I>) of VSVs to cover media of various density ranges, as found in the whole body. <B>Methods:</B> The VSVs were precalculated using GATE Monte Carlo simulation and were convoluted with the time-integrated activity to generate density-specific dose maps. CT-based segmentation was performed to generate a binary mask image for each density region. The final dose map was acquired by the summation of <I>N</I> segmented density-specific dose maps. We tested several sets of VSVs with different densities: <I>N</I> = 1 (single water VSV), 4, 6, 8, 10, and 20. To validate the proposed method, phantom and patient studies were conducted and compared with the direct Monte Carlo approach, which was considered the ground truth. Finally, dosimetry on 10 patients was performed using the multiple VSV approach and compared with the single VSV and organ-based approaches. Errors at the voxel and organ levels were reported for 8 organs. <B>Results:</B> In the phantom and patient studies, the multiple VSV approach showed significant decreases in voxel-level errors, especially for the lung and bone regions. As the number of VSVs increased, voxel-level errors decreased, although some overestimations were observed at the lung boundaries. For the multiple VSVs (<I>N</I> = 8), we achieved a voxel-level error of 2.06%. In the dosimetry study, our proposed method showed greatly improved results compared with single VSV and organ-based dosimetry. Errors at the organ level were −6.71%, 2.17%, and 227.46% for single VSV, multiple VSV, and organ-based dosimetry, respectively. <B>Conclusion:</B> The multiple VSV approach for heterogeneous media with nonuniform activity distributions offers fast personalized dosimetry at the whole-body level, yielding results comparable to those of the direct Monte Carlo approach.</P>
더보기분석정보
서지정보 내보내기(Export)
닫기소장기관 정보
닫기권호소장정보
닫기오류접수
닫기오류 접수 확인
닫기음성서비스 신청
닫기음성서비스 신청 확인
닫기이용약관
닫기학술연구정보서비스 이용약관 (2017년 1월 1일 ~ 현재 적용)
학술연구정보서비스(이하 RISS)는 정보주체의 자유와 권리 보호를 위해 「개인정보 보호법」 및 관계 법령이 정한 바를 준수하여, 적법하게 개인정보를 처리하고 안전하게 관리하고 있습니다. 이에 「개인정보 보호법」 제30조에 따라 정보주체에게 개인정보 처리에 관한 절차 및 기준을 안내하고, 이와 관련한 고충을 신속하고 원활하게 처리할 수 있도록 하기 위하여 다음과 같이 개인정보 처리방침을 수립·공개합니다.
주요 개인정보 처리 표시(라벨링)
목 차
3년
또는 회원탈퇴시까지5년
(「전자상거래 등에서의 소비자보호에 관한3년
(「전자상거래 등에서의 소비자보호에 관한2년
이상(개인정보보호위원회 : 개인정보의 안전성 확보조치 기준)개인정보파일의 명칭 | 운영근거 / 처리목적 | 개인정보파일에 기록되는 개인정보의 항목 | 보유기간 | |
---|---|---|---|---|
학술연구정보서비스 이용자 가입정보 파일 | 한국교육학술정보원법 | 필수 | ID, 비밀번호, 성명, 생년월일, 신분(직업구분), 이메일, 소속분야, 웹진메일 수신동의 여부 | 3년 또는 탈퇴시 |
선택 | 소속기관명, 소속도서관명, 학과/부서명, 학번/직원번호, 휴대전화, 주소 |
구분 | 담당자 | 연락처 |
---|---|---|
KERIS 개인정보 보호책임자 | 정보보호본부 김태우 | - 이메일 : lsy@keris.or.kr - 전화번호 : 053-714-0439 - 팩스번호 : 053-714-0195 |
KERIS 개인정보 보호담당자 | 개인정보보호부 이상엽 | |
RISS 개인정보 보호책임자 | 대학학술본부 장금연 | - 이메일 : giltizen@keris.or.kr - 전화번호 : 053-714-0149 - 팩스번호 : 053-714-0194 |
RISS 개인정보 보호담당자 | 학술진흥부 길원진 |
자동로그아웃 안내
닫기인증오류 안내
닫기귀하께서는 휴면계정 전환 후 1년동안 회원정보 수집 및 이용에 대한
재동의를 하지 않으신 관계로 개인정보가 삭제되었습니다.
(참조 : RISS 이용약관 및 개인정보처리방침)
신규회원으로 가입하여 이용 부탁 드리며, 추가 문의는 고객센터로 연락 바랍니다.
- 기존 아이디 재사용 불가
휴면계정 안내
RISS는 [표준개인정보 보호지침]에 따라 2년을 주기로 개인정보 수집·이용에 관하여 (재)동의를 받고 있으며, (재)동의를 하지 않을 경우, 휴면계정으로 전환됩니다.
(※ 휴면계정은 원문이용 및 복사/대출 서비스를 이용할 수 없습니다.)
휴면계정으로 전환된 후 1년간 회원정보 수집·이용에 대한 재동의를 하지 않을 경우, RISS에서 자동탈퇴 및 개인정보가 삭제처리 됩니다.
고객센터 1599-3122
ARS번호+1번(회원가입 및 정보수정)